Maytag W10274252A 사용자 설명서

다운로드
페이지 16
3
Product Dimensions
Installation Clearances
IMPORTANT: If installing a range hood or microwave hood 
combination above the range, follow the range hood or 
microwave hood combination installation instructions for 
dimensional clearances above the cooktop surface.
NOTES: After making the countertop cutout, some installations 
may require notching down the base cabinet side walls to clear 
the burner box. To avoid this modification, use a base cabinet 
with sidewalls wider than the cutout.
If cabinet has a drawer, a 3¼" (9.6 cm) depth clearance from the 
countertop to the top of the drawer (or other obstruction) in base 
cabinet is required.
Electrical Requirements
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
Check with a qualified electrical installer if you are not sure the 
cooktop is properly grounded.
Make sure that the electrical connection and wire size are 
adequate and in conformance with the National Electrical Code, 
ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, 
Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest 
edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Before You Make the Electrical Connection:
To properly install your cooktop, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
A. 21" (53.3 cm)
B. 30" (76.2 cm)
36" (91.4 cm)
C. 3¼" (8.3 cm)
A. 30" (76.2 cm) models on 30" (76.2 cm) models; 36" (91.4 cm) on 
36" (91.4 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform 
and bottom of uncovered wood or metal cabinet (24" [61 cm] 
minimum clearance if bottom of wood or metal cabinet is covered 
by not less than 
¹⁄₄" [0.6 cm] flame retardant millboard covered with 
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless 
steel or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper cabinet depth
E. 3" (7.6 cm)
F. 19
¹³⁄₁₆" (50.3 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to 
countertop within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of 
countertop
I. Junction box or outlet; 10" (25.4 cm) from right side of cabinet
J. 28
⁵⁄₁₆" (71.9 cm) on 30" (76.2 cm) models; 34⁷⁄₈" (88.6 cm) on 36" 
(91.4 cm) models
K. 1" (2.5 cm) minimum distance to nearest left and right side 
combustible surface above cooktop
L. 1" (2.5 cm) minimum clearance between back wall and countertop
C
A
B
B
D
A
C
E
F
J
K
G
L
I
H
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death, 
fire, or electrical shock.