Fisher & Paykel CG603 사용자 설명서
4
a
e
c
d
b
f
g
Clearances
a
600 mm minimum from top of trivet to rangehood.
750 mm minimum from top of trivet to overhead exhaust fan. (Fisher & Paykel splashbacks are
750 mm high).
750 mm minimum from top of trivet to overhead exhaust fan. (Fisher & Paykel splashbacks are
750 mm high).
b
600 mm minimum from top of trivet to downward facing combustable surface. (450 mm
minimum if protected by tiles or fire resistant materials).
minimum if protected by tiles or fire resistant materials).
CG603 SERIES
CG903 SERIES
CG913 SERIES
c
Clearance from side edge of
product to any combustible surface
product to any combustible surface
130 mm
120 mm
80 mm
d
Clearance from rear edge of
product to any combustible surface
product to any combustible surface
100 mm
90 mm
90 mm
Clearance from rear edge of
product to any non-combustible
surface
product to any non-combustible
surface
10 mm
10 mm
10 mm
e
Clearance below benchtop to any
combustible surface
combustible surface
60 mm
60 mm
81 mm
Clearance below benchtop to
F&P DishDrawer® or F&P oven
F&P DishDrawer® or F&P oven
45 mm
45 mm
81 mm
f
Ensure there is an earthed power outlet within 900 mm of the rear right-hand corner of the
product. When used with a flexible hose, the connector on the wall should be between 800
mm to 850 mm above the floor and in the region outside the width of the appliance to a
distance of 250 mm. This should be accessible with the appliance installed.
mm to 850 mm above the floor and in the region outside the width of the appliance to a
distance of 250 mm. This should be accessible with the appliance installed.
g
When protecting a wall with non-combustible material it must be at least 150 mm high.