Clearances
a
600 mm minimum from top of trivet to rangehood.
750 mm minimum from top of trivet to overhead exhaust fan.  (Fisher & Paykel splashbacks are 
750 mm high).
b
600 mm minimum from top of trivet to downward facing combustable surface.  (450 mm 
minimum if protected by tiles or fire resistant materials).
CG603 SERIES
CG903 SERIES
CG913 SERIES
c
Clearance from side edge of 
product to any combustible surface
130 mm
120 mm
80 mm
d
Clearance from rear edge of 
product to any combustible surface
100 mm
90 mm
90 mm
Clearance from rear edge of 
product to any non-combustible 
surface
10 mm
10 mm
10 mm
e
Clearance below benchtop to any 
combustible surface
60 mm
60 mm
81 mm
Clearance below benchtop to 
F&P DishDrawer® or F&P oven
45 mm
45 mm
81 mm
f
  Ensure there is an earthed power outlet within 900 mm of the rear right-hand corner of the 
product.  When used with a flexible hose, the connector on the wall should be between 800 
mm to 850 mm above the floor and in the region outside the width of the appliance to a 
distance of 250 mm.  This should be accessible with the appliance installed.
g
 When protecting a wall with non-combustible material it must be at least 150 mm high.