The operation of the appliance, including 
the ignition system, must be tested 
before installation is complete.
If after following the instructions given, 
satisfactory performance cannot be 
obtained, contact the local gas authority 
or your local Approved Service Agent for 
advice and assistance.
Conversion to Different Gas Type
  Burners can be used with NG or LPG, 
provided that the orifices appropriate for the 
gas supply are installed. 
  To change the orifices, you will need a 7 mm 
box spanner (and a 10 mm ring spanner for 
CG913TM).
1
  Turn off the main electrical supply.
 
WARNING!
Electrical Shock Hazard.
Disconnect product from main power 
supply before continuing. 
2
  Ensure all gas valves are turned off.
3
  Remove all trivets and burner heads.
4
  Pull off knobs.
5
  Unscrew the orifices and replace them 
with the correct ones.  (size numbers are 
stamped on the side, eg. 70= 0.70 mm) 
(see figure 1)
6
  Remove the 2 screws holding each burner 
(3 on the wok burner).
7
  Lift hob tray from the product.
WARNING!
Cut Hazard.
Beware of sharp edges. 
8
  Replace the wok orifice with the correct 
one using a 10 mm spanner.
9
  Reset the venturi (see fig.2).  Loosen the 
venturi screw, move the venturi toward the 
orifice approx. 2 mm.
10
  To refit the CG913 series hob tray, repeat 
steps 6 and 7 in reverse.
11
  Check insulation resistance and earth 
continuity.
Natural Gas
  For Natural Gas usage the gas supply is 
connected to the regulator which is supplied 
loose with a built in test point - 1kPa (4” WG) 
and the inlet connection of 1/2 “ B.S.P. (male 
thread). Do not over tighten.
  The test point pressure should be preset 
to 1.0 kPa with the wok and semi - rapid 
burners operating at maximum.
LP Gas
  For LPG usage the gas supply for the 
appliance must be regulated to a pressure 
of 2.75kPa (11” WG).  See ‘Conversion to a 
different gas type’ .
Gas Supply Connection Check
  The connection point shall be accessible 
with the appliance installed.
  To enable the gas supply to be readily shut 
off, the gas supply  must be connected with 
an isolating valve close to the product. 
  After installation and making all connections 
check thoroughly for possible leaks. 
1
 Turn all control knobs on the unit to “off” 
position. 
2
 Open the valve on the gas supply. 
3
 Using a suitable leak detection fluid solution 
(e.g. Rocol) check each gas connection one 
at a time by brushing the solution over the 
connection. 
4
 The presence of bubbles will indicate a leak. 
Tighten the fitting and recheck for leaks. 
Ensure the washer (supplied) is located 
between elbow and product gas inlet. 
5
 Turn on each gas valve and light each 
burner. 
6
 Check for a clear blue flame without yellow 
tipping.  If burners show any abnormalities, 
check that they are located and assembled 
properly. Check correct orifices are installed.
Installation Instructions
continued...