C
G603, C
G903 
Standards Requirements
Australian and New Zealand Gas Installation 
Standards (AS5601, NZS 5261) require a 
cooktop to be installed so that the surface 
temperature of any nearby combustible 
surface will not exceed 65
o
C above ambient. 
Typically this is achieved by:
A
 
Having the cooktop spaced away from 
the wall (see “Clearances” for dimensions) 
[Dimension 
c
 and 
d
]
OR
B
  by protecting the wall, to at least 150 mm 
high [Dimension 
g
] along it’s length, with 
non-combustible surface materials, such as:
- 5 mm thick ceramic tiles alone are 
adequate.
- Tempered glass or sheetmetal (min. 0.4 mm 
thick) is acceptable when used in front of a 
fire resistant material.
- Fisher & Paykel Splashback (not available 
in Australia): This is stainless steel with a 10 
mm air gap to the wall.  When used with 
a 10 mm gap behind the product to the 
front of the splashback.  (Only with SB90 
series and SB1216 splashbacks.)
These products meet the Standards 
requirements when installed to  the 
dimensions in these Instructions. (They have 
been tested by an Independent Testing Lab).
Clamping Down the Cooktop
This cooktop is supplied with fastening 
clamps that will cope with a bench thickness 
of 20-50 mm.  For benchtops thicker than 50 
mm, recess the underside to a thickness of 
20-50 mm.
Gas Supply Connection
  This cooktop is supplied set up for 
Natural Gas but is suitable for installation 
with either Natural Gas or LPG.  Refer to 
relevant table for pressures and appropriate 
orifice sizes. 
  Gas connection to the product MUST use 
the elbow supplied.  The regulator will not 
seal if installed without it.
  Ensure the blue washer (supplied) is located 
between the elbow (supplied) and product 
inlet as below.  Failure to use this washer 
will cause the product to leak.  Tighten the 
floating nut to firm finger tight, plus an 
additional 
1
/
4
 turn (90
o
).
    
  After installation, make sure all 
connections are gas tight.
  A duplicate data plate enclosed inside the 
accessories pack should be placed on an 
accessible surface adjacent to the cooktop.
Flexible Hoses
  Flexible hose assemblies should be AS/NZS 
1869 Class B or Class D certified.
  Flexible hoses should not be exposed to 
temperatures exceeding their certified value.  
They should not touch hot surfaces on the 
cooktop or neighbouring products.
  Flexible hoses should not be subject to 
abrasion, kinking or permanent deformation.
Installation Instructions
20 mm
50 mm
recessed to 
50 mm
Blue washer
Elbow (
1
/
2
” BSP male)
Gas Inlet (
1
/
2
” BSP internal thread)
C