Installation Instructions
Minimum Setting or Turn Down
  This has been set at the factory for NG but 
may need adjusting for local conditions.  
  When converting to LPG, the minimum 
setting MUST be reset for each burner.
  To adjust the minimum setting you will need 
a Ø 2.5 x 45 mm screwdriver.
1
  Ignite the burner and set the knob to its 
minimum position. 
2
  Remove the knob.
3
  Rotate the turn down screw slowly until 
a minimum regular flame is achieved. 
(The flame will diminish when the screw 
is turned clockwise and increase when 
turned anti-clockwise (see fig.6).  
4
  Replace the knob.
5
  When the setting is right check regulation 
by quickly rotating the knob from the 
maximum to the minimum delivery 
position.  The flame must not go out.
figure 6
12
  Turn on main electrical supply and light the 
burners.
13
  Important!  Reset the minimum setting 
(see ‘Minimum Setting or Turndown’).
14
  Check all burners have good flame (see 
fig.3,4,5).
 
Note: CG913TM models may require 
progressive venturi adjustment on the wok 
burner:
 
Fig.3 Lifting Off - move the venturi closer to 
the orifice.
 
Fig.4 Yellow Tipping - move the venturi 
away from the orifice.
 
Fig.5 Good Flame.
The label supplied with the orifices should 
be placed over the existing gas type label 
located on the underside of the product to 
indicate the gas change. 
figure 3
figure 4
figure 5
Venturi
figure 2
figure 1