Avaya 555-231-743 사용자 설명서

다운로드
페이지 274
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations  
555-231-743  
Issue 1
November 2000
Translations and Testing 
217
Switch-to-PMS Link Translations 
Switch-to-PMS Link Testing with the
RS232 Mini-Tester
Using the RS232 Mini-Tester (see the Note on 
), check the status of the 
PMS link. The leads marked with an asterisk are controlled by the switch, and the 
PMS controls the other leads. If any switch leads are dark, there is no connection.
!
CAUTION:
After using a mini-tester to check data leads, you MUST remove the 
mini-tester from the connection. DO NOT leave the mini-tester in-line during 
actual operation.
If the link to a PMS is active, the mini-tester should show the following. The 
Physical Link State should be up, and the Protocol State should be up. If this is 
the status of the link, proceed to 
Otherwise, look at the other results in this section.
If the link is idle, the mini-tester may show the following. The Physical Link State 
will be down, and the Protocol State will be down. Possible causes may be that 
the switch or PMS are not administered correctly, or the PMS software is not 
running.
NOTE:
The CTS lead shows green when used with an 8400B. RTS will be lit on the 
front panel of the 7400A and 7400B. 
TD
RTS
DTR
RD*
CTS*
DSR*
CD*
green
green
red
green
red
green
green
TD
RTS
DTR
RD*
CTS*
DSR*
CD*
red
red
red
red
red
red
red