Avaya 555-231-743 사용자 설명서

다운로드
페이지 274
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations  
555-231-743  
Issue 1
November 2000
Translations and Testing 
219
Switch-to-PMS Link Translations 
Netcon and Data Module Testing
If the switch-to-PMS link uses TCP/IP, skip this test. To test the netcon and the 
data modules for a DCP link, do the following:
1.
Use the status data-module XXXX command (where XXXX is the 
extension of the netcon data module).
If the status message shows that the netcon data module is in the in-
service/active state and shows the connected port of the actual data 
module, this indicates that there was an available netcon data channel and 
that the data module extension has been added to the hospitality 
parameters screen.
If the status message shows that the netcon data module is in the in-
service/idle state, the PMS link may have been busied out. Release the 
PMS link.
2.
Use the status data-module XXXX command (where XXXX is the 
extension of the PMS link data module).
If the status message shows that the PMS link data module is in the in-
service/active state and shows the connected port of the netcon, this 
indicates that the PMS link data module extension has been added to the 
hospitality parameters screen.
If the status message shows that the netcon data module is in the in-
service/idle state, the PMS link may not be providing DTR. Contact the 
PMS vendor for assistance.
3.
Dial the netcon extension and the PMS link data module extension. If these 
facilities are operational, you will hear a high-pitched data tone.
status data-module 7891
DATA-MODULE STATUS
Data Ext/Stn Ext for Stn DM: 7891
Service State: in-service/active
Port/Channel Number: 01A0502
Maintenance Busy? no
CF Destination Ext:
Connected Ports: 01AXX01
status data-module 7899
DATA-MODULE STATUS
Data Ext/Stn Ext for Stn DM: 7899
Service State: in-service/active
Port/Channel Number: 01AXX01
Maintenance Busy? no
CF Destination Ext:
Connected Ports: 01A0502