Avaya 555-231-743 사용자 설명서

다운로드
페이지 274
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations  
555-231-743  
Issue 1
November 2000
Translations and Testing 
220
Switch-to-PMS Link Translations 
PMS Testing and Status
Use the test pms command to test the PMS link. If the link is not active, this 
command sometimes causes the link to be established. The PMS test (Test 215) 
must pass before you proceed with further testing.
Use the status pms-link command to display the current status of the PMS link. 
The following is an example of that screen:
The fields are defined as follows:
Physical Link State
 — If the link state is 
Up
, the transmit/receive 
lamps will be flashing, and all lamps except for the ringing indicator lamp 
will be lit. This indicates that the link is active, and the call has been placed 
from the netcon to the data module.
Protocol State
 — If the protocol state is 
Up
, the data module carrier 
detect lamp is lit, and at least one status inquiry message has been 
received and understood from the PMS. The data module transmit/receive 
lamps will be flashing if the switch is talking with the PMS. If the lamps stay 
on longer than the link idle timeout setting (usually 20 seconds), the switch 
and the PMS are communicating. If the TD lamp flashes every 15 to 20 
seconds, this indicates that the PMS is sending data to the switch.
Number of Retries
 — This count increments every 5 minutes for the 
first 12 retries, and then every 15 minutes until the link is established. A 
high number of retries could indicate that the netcon data channel is not 
available because too many resources are assigned, or the data module 
could be busy. If there are no retries to report, this field is not displayed.
Maintenance Busy?
 — This field shows whether the link is currently 
maintenance busied-out. If the link is not maintenance busied-out, this field 
is not displayed.
Database Swapping?
 — If the field displays 
yes
, the room images are 
being transmitted between the switch and the PMS. If the field displays 
pending
, the database swap has been requested by the switch. If the field 
displays 
no
, the PMS link is up.
status pms-link
PMS LINK STATUS
Physical Link State: Down
Protocol State: Down
Maintenance Busy? No
Database Swapping? No