Fujitsu S510M 사용자 가이드
ScanSnap S510M for Mac Getting Started | 17
Pad ASSY (x1)
Clean the Pad ASSY by wiping downward. When
cleaning the Pad ASSY, take care to prevent the
cloth from catching on the pick spring.
cleaning the Pad ASSY, take care to prevent the
cloth from catching on the pick spring.
Glass (x2 on the ADF and the base unit)
Clean lightly.
Pick roller (x1)
Clean lightly taking care not to scratch and damage
the surface of the roller. Take particular care when
cleaning the Pick roller as black debris on the roller
adversely affects the pickup performance.
the surface of the roller. Take particular care when
cleaning the Pick roller as black debris on the roller
adversely affects the pickup performance.
Plastic rollers (x4)
Clean them lightly while rotating the rollers with
your fingers. Take care not to roughen the surface of
the rollers. Take particular care when cleaning the
plastic rollers, as black debris on the rollers
adversely affects the pickup performance.
your fingers. Take care not to roughen the surface of
the rollers. Take particular care when cleaning the
plastic rollers, as black debris on the rollers
adversely affects the pickup performance.
Turn on the scanner before cleaning the
following locations. Clean the following rollers,
while rotating them.
following locations. Clean the following rollers,
while rotating them.
Feed rollers (x2)
Clean the rollers lightly taking care not to roughen
the surface of the rollers. Take particular care when
cleaning the feed rollers, as black debris on the
rollers adversely affects the pickup performance.
the surface of the rollers. Take particular care when
cleaning the feed rollers, as black debris on the
rollers adversely affects the pickup performance.
Eject rollers (x2)
Clean the rollers lightly taking care not to roughen
the surface of the rollers. Take particular care when
cleaning the eject rollers, as black debris on the
rollers adversely affects the pickup performance.
the surface of the rollers. Take particular care when
cleaning the eject rollers, as black debris on the
rollers adversely affects the pickup performance.
To rotate the feed rollers and the eject rollers, press
the [POWER] button while holding down the [SCAN]
button.
As a guideline, six presses of the [POWER] button
make the rollers to rotate one full turn.
the [POWER] button while holding down the [SCAN]
button.
As a guideline, six presses of the [POWER] button
make the rollers to rotate one full turn.
ATTENTION
Connect the AC adapter and AC cable only
when cleaning the Feed rollers and the Eject
rollers.
when cleaning the Feed rollers and the Eject
rollers.
3. Close the ADF.
Ö
You should hear the ADF click into position when
it returns to its original position.
it returns to its original position.
ATTENTION
When you closed the ADF, make sure that it is
completely closed. Otherwise, paper jams or other
feeding troubles may occur.
completely closed. Otherwise, paper jams or other
feeding troubles may occur.
5.4. Cleaning the Carrier Sheet
If the Carrier Sheet is used extensively, dirt and dust may
stick onto the surface or the interior and cause scanning
errors. Clean it regularly.
<Cleaning method>
Use a dry, soft cloth, or a soft cloth slightly moistened with
Cleaner F1 or a mild detergent to lightly clean off the dirt
and dust from the surface and the interior of the Carrier
Sheet.
stick onto the surface or the interior and cause scanning
errors. Clean it regularly.
<Cleaning method>
Use a dry, soft cloth, or a soft cloth slightly moistened with
Cleaner F1 or a mild detergent to lightly clean off the dirt
and dust from the surface and the interior of the Carrier
Sheet.
●
Never use paint thinner or other organic solvents.
●
Do not rub too hard. Otherwise, the Carrier Sheet
may be scratched or be deformed.
may be scratched or be deformed.
●
After cleaning the interior of the Carrier Sheet
with Cleaner F1 or a mild detergent, dry the
Carrier Sheet completely before closing it.
with Cleaner F1 or a mild detergent, dry the
Carrier Sheet completely before closing it.
●
As a guideline, it is recommended to replace the
Carrier Sheet every 500 scans.
Refer to "6.4. Purchasing the Carrier Sheet" for
details on purchasing a Carrier Sheet.
Carrier Sheet every 500 scans.
Refer to "6.4. Purchasing the Carrier Sheet" for
details on purchasing a Carrier Sheet.
c
While holding
down the [SCAN]
button.
down the [SCAN]
button.
d
...press the
[POWER] button.
ADF