Fantom Drives mgd-16fc16a 사용자 가이드

다운로드
페이지 160
 
FIBRE-to-SAS/SATA RAID SUBSYSTEM 
 
146 
User Manual 
 
10.2.2   Warnings 
 
NOTE: The Alert Messages displayed here are example Alert 
Messages. 
 
Notification Message 
Action to be taken 
Disk in bay <number> has 
excessive errors 
Backup data, schedule a disk replacement. 
Disk in bay <number> is running 
out of reallocation blocks 
Backup data, schedule a disk replacement. 
Disk in bay <number> has run out 
of reallocation blocks 
Backup data, schedule a disk replacement. 
Disk in bay <number> has failed 
Backup data, schedule a disk replacement. 
Disk in bay <number> is missing 
Check to see if a rebuild is in progress for the 
effected RAID. 
Reseat the missing disk. 
Backup data, schedule a disk replacement. 
Power Supply Module in slot 
<number> is not working properly
Reseat the power cord on both ends. 
Verify that power is being supplied from the 
power socket. 
Schedule a PSU module replacement. 
Fan in slot <number> is not 
working properly 
Schedule a fan module replacement. 
NVRAM battery is exhausted and 
needs replacement 
Schedule NVRAM Battery replacement. 
NVRAM checksum invalid, 
restoring default settings 
No action required, occurs immediately after the 
battery has been replaced. 
The serial number on this system 
is incorrect 
Occurs immediately after the battery has been 
replaced, controller serial number needs to be 
entered by service engineer. 
Call Tech Support for help. 
The temperature in the system has  Ensure that all the disk bays have either disks or