147
exceeded <threshold value>
threshold
threshold
dummy shuttles installed.
Cool the room containing the system.
The temperature in the system has
dropped below 10C/50F
dropped below 10C/50F
Heat the room containing the system.
RAID <name> rebuild failed to
complete
complete
Usually followed by another warning indicating
reason.
reason.
Follow action for the other warning.
RAID <name> initialization failed
to complete
to complete
Usually followed by another warning indicating
reason.
reason.
Follow action for the other warning.
RAID <name> verify failed to
complete
complete
Usually followed by another warning indicating
reason.
reason.
Follow action for the other warning.
RAID <name> expand failed to
complete
complete
Usually followed by another warning indicating
reason.
reason.
Follow action for the other warning.
RAID <name> is degraded due to
disk failures
disk failures
Backup data, schedule a disk replacement.
RAID <name> is inaccessible due
to disk failures
to disk failures
Schedule multiple disk replacements.
Restore data from last backup.
RAID <name> has no spare
available
available
Assign a spare disk to the RAID.
Cannot start scheduled verify on
RAID <name>
RAID <name>
If RAID is Initialising, rebuilding, or expanding,
verify will run on next scheduled verify.
verify will run on next scheduled verify.
Otherwise backup data, schedule disk
replacement.
replacement.
Controller hardware error
Schedule controller replacement.
Firmware ID does not match; the
binary is not for this product
binary is not for this product
Get correct firmware and download to controller.
Firmware download checksum
failed, the binary may be
corrupted
failed, the binary may be
corrupted
Get a different firmware file and download to
controller.
controller.