147 
 
exceeded <threshold value> 
threshold 
dummy shuttles installed. 
Cool the room containing the system. 
The temperature in the system has 
dropped below 10C/50F 
Heat the room containing the system. 
RAID <name> rebuild failed to 
complete 
Usually followed by another warning indicating 
reason. 
Follow action for the other warning. 
RAID <name> initialization failed 
to complete 
Usually followed by another warning indicating 
reason. 
Follow action for the other warning. 
RAID <name> verify failed to 
complete 
Usually followed by another warning indicating 
reason. 
Follow action for the other warning. 
RAID <name> expand failed to 
complete 
Usually followed by another warning indicating 
reason. 
Follow action for the other warning. 
RAID <name> is degraded due to 
disk failures 
Backup data, schedule a disk replacement. 
RAID <name> is inaccessible due 
to disk failures 
Schedule multiple disk replacements. 
Restore data from last backup. 
RAID <name> has no spare 
available 
Assign a spare disk to the RAID. 
Cannot start scheduled verify on 
RAID <name> 
If RAID is Initialising, rebuilding, or expanding, 
verify will run on next scheduled verify. 
Otherwise backup data, schedule disk 
replacement. 
Controller hardware error 
Schedule controller replacement. 
Firmware ID does not match; the 
binary is not for this product 
Get correct firmware and download to controller. 
Firmware download checksum 
failed, the binary may be 
corrupted 
Get a different firmware file and download to 
controller.