138 
   
 
Calibrate is highlighted on the device configuration menu (left).  Cali-
bration menu (right) with calibration instructions listed at the top.
 
3-Point Calibration 
3-point calibration is designed for tanks that vary in shape from the top 
to the bottom. You can begin calibration at any point in the 3-point 
process, but we recommend starting calibration with an empty tank. In 
a 3-point calibration, you will set three points, one each for empty, half 
and full levels. 
1. Press 
MENU| MENU
, use 
↓ ↑  to select 
NMEA
 
2000
 and press 
ENT
2. Highlight 
B
US 
S
ETUP
 and press 
ENT
, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page. 3. 
Select the EP-15 Fluid Level and press 
ENT
4. Press 
↓ to select 
C
ALIBRATE
 and press 
ENT
. The Device Calibration 
menu will appear. 
5. Highlight 
N
UM 
P
TS
, press 
ENT
 and select 
3
. Press 
ENT
6. 
Make sure your tank is empty, then highlight
 
F
LUID 
L
EVEL
 
and press
 
ENT
.
 Select 
E
MPTY LEVEL 
and press 
ENT.  
7. 
Select
 
C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Empty Level Calibration Completed. Press 
ENTER
.
 
8. 
Add half a tank of fuel, highlight
 
F
LUID 
L
EVEL
 
and press
 
ENT
.
 
Select
 
H
ALF LEVEL 
and press
 
ENT.  
9.
 
Select
 
C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Half Level Calibration Completed. Press 
ENT
10. Fill up the tank, then
 
highlight
 
F
LUID 
L
EVEL
 
and press
 
ENT
.
 
Select
 
F
ULL LEVEL 
and press
 
ENT