9.
 
Select
 
C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Qtr Level Calibration Completed. Press 
ENT
10. Add another quarter tank of fuel, which should raise the fuel level 
to half a tank. Highlight
 
F
LUID 
L
EVEL
 
and press
 
ENT
.
 
Select
 
H
ALF LEVEL 
and 
press
 
ENT
11. 
Highlight
 
C
ALIBRATE
 
and press
 ENT
. The following message will ap-
pear: Half Level Calibration Completed. Press 
ENT
12. Add another quarter tank of fuel, which should raise the fuel level 
to 3 quarters of a tank. Highlight
 
F
LUID 
L
EVEL
 
and press
 
ENT
.
 
Select
 
3
 
Q
TR 
L
EVEL 
and press
 
ENT
13. 
Select
 
C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Qtr Level Calibration Completed. Press 
ENT
14. Top off the tank, highlight
 
F
LUID 
L
EVEL
 
and press
 
ENT
.
 
Select
 
F
ULL 
L
EVEL 
and press
 
ENT
15. 
Select
 
C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Full Level Calibration Completed. Press 
ENT
, then press 
EXIT
 repeat-
edly to get back to the main display. 
Fuel Flow Calibration in a Suzuki Engine Interface 
The default calibration for the Suzuki Engine Interface is adequate in 
most cases, but if Fuel Used readings are off by more than 3 percent, 
calibration is recommended. 
To check engine interface accuracy: 
Select Fuel Used to be shown as Overlay Data on your unit's main dis-
play. Refer to the Overlay Data segment of this manual for instructions 
on how to select Fuel Used data as Overlay Data.  
1. After selecting Fuel Used as overlay data, fill up your tank and press 
MENU
|
MENU
.  
2. Select 
NMEA
 
2000
 and press 
ENT
3. Highlight 
F
UEL 
M
ANAGEMENT 
and press 
ENT
. Select 
T
ANK 
L
OCATION
 and 
press 
ENT
.  
4. Use 
↑ ↓ to select the location (Port, Center or Starboard) of the en-
gine interface you want to calibrate and press 
ENT
5. Highlight 
F
ILL 
T
ANK
 and press 
ENT
. The following confirmation mes-
sage will appear: Are you sure you wish to Fill Tank?  
6. Select 
Y
ES
 and press 
ENTER
. The following confirmation message will 
appear: Do you wish to re-calibrate the device? 
7. Highlight 
N
O
 and press 
ENT
. Take your vessel out on the water and 
burn at least five gallons of fuel. Be sure you run only ONE engine 
— the engine connected to your engine interface.