5-Point Calibration 
5-point calibration is best suited tanks that vary greatly in shape from 
top to bottom. You can begin calibration at any point in the 5-point 
calibration process. We recommend starting calibration with an empty 
tank. In a five-point calibration you will set five points: Empty Level, 1 
Qtr Level, Half Level, 3 Qtr Level and Full Level. In a 5-point calibra-
tion, you will have four calibration points left after calibrating your 
tank's Empty Level.  
To figure out how much fuel you should add for the remaining steps of 
the calibration process, divide the total capacity of you tank by four. So, 
if you have a 40-gallon tank, each quarter tank will equate to 10 gal-
lons. 
1. Press 
MENU| MENU
, use 
↓ ↑  to select 
NMEA
 
2000
 and press 
ENT
2. Highlight 
B
US 
S
ETUP
 and press 
ENT
, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page.   3. 
Select the desired EP-15 Fluid Level and press 
ENT
4. Press 
↓ to select 
C
ALIBRATE
 and press 
ENT
. The Device Calibration 
menu will appear. 
5. Highlight 
N
UM 
P
TS
, press 
ENT
 and select 
5
. Press 
ENT
6. 
Make sure your tank is empty, then
 
highlight
 
F
LUID 
L
EVEL
 
and press
 
ENT
.
 
Select
 
E
MPTY LEVEL 
and press
 
ENT.  
7.
 
Select
 
C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Empty Level Calibration Completed. Press 
ENT
.
 
8. 
Add 1 quarter tank of fuel, highlight
 
F
LUID 
L
EVEL
 
and press
 
ENT
.
 
Select
 
1
 
Q
TR 
L
EVEL 
and press 
ENT.