1-15 
To do… 
Use the command… 
Remarks 
Enable global MPLS TE 
mpls te 
Required 
Disabled by default  
Exit to system view 
quit 
–– 
Enter the interface view of an 
MPLS TE link 
interface interface-type 
interface-number
 
–– 
Enable interface MPLS TE 
mpls te
 
Required 
Disabled by default  
Exit to system view 
quit 
–– 
Create a tunnel interface and 
enter its view 
interface tunnel 
tunnel-number 
Required 
Assign an IP address to the 
tunnel interface 
ip address ip-address 
netmask
 
Required 
Set the tunnel protocol to MPLS 
TE 
tunnel-protocol
 mpls te 
Required 
Configure the destination 
address of the tunnel 
destination ip-address 
Required 
Configure the tunnel ID of the 
tunnel 
mpls te tunnel-id
 tunnel-id 
Required 
Submit the current tunnel 
configuration 
mpls te commit 
Required 
 
 
z
 
Depending on the MPLS TE signaling protocol a tunnel uses, the basic capabilities you configured 
in this section may be inadequate for the tunnel to work and you may need to make extra 
configurations.  
z
 
For information about tunnel interfaces, refer to Tunneling Configuration in the IP Services Volume
 
Creating MPLS TE Tunnel over Static CR-LSP 
Creating MPLS TE tunnels over static CR-LSPs does not involve configuration of tunnel constraints or 
the issue of IGP TE extension or CSPF. What you need to do is to create a static CR-LSP and a TE 
tunnel using static signaling and then associate them.  
Despite its ease of configuration, the application of MPLS TE tunnels over static CR-LSPs is restricted 
because they do not accept bandwidth constraints and cannot dynamically adapt to network changes.  
Static CR-LSPs are special static LSPs. They share the same constraints and use the same label 
space. 
Configuration Prerequisites 
Before making the configuration, do the following:  
z
 
Configure static routing or an IGP protocol to make sure that all LSRs are reachable.