Example
# Configure the timeout time in a DHCP probe as 10000 milliseconds.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type dhcp
[Syaname-nqa-admin-test-dhcp] probe timeout 10000 
reaction
Syntax
reaction item-num checked-element probe-fail threshold-type consecutive 
occurrences [ action-type { none | trigger-only } ]
undo reaction item-num
View
DHCP/DLSw/FTP/HTTP/ICMP-echo/SNMP/TCP/UDP-echo test type view
Parameter
item-num: Number of the collaboration entry, in the range 1 to 10.
checked-element: Type of the monitored element in collaboration. At present, 
the type of the monitored element can be probe failure only.
probe-fail: The type of the monitored element is probe failure.
threshold-type consecutive: Threshold type is consecutive probe failures.
occurrences: Number of consecutive probe failures, in the range 1 to 16.
action-type: Triggered action type, defaulting to none.
none: No actions.
trigger-only: Triggers collaboration between other modules only.
Description
Use the reaction command to establish a collaboration entry to monitor the 
probe results of the current test group. If the number of consecutive probe failures 
reaches the threshold, collaboration with other modules is triggered.
Use the undo reaction command to remove the collaboration entry.
By default, no collaboration entries are configured.
Note that you cannot modify the content of a collaboration object using the 
reaction command after the collaboration object is created.
Related command:
Example
# Create collaboration object 1. If the number of consecutive probe failures 
reaches 3, collaboration with other modules is triggered.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type tcp