15 Baffle plate
16 Lid of the water filter container
17 Intermediate filter
18 Floor nozzle, reversible
19 Release to adjust the telescoping vacu-
um pipe
20 Telescopic suction pipe
21 False air slide
22 Handle
23 Suction hose
Additional scope of supply with ap-
pliance 1.195-202.0
24 Turbo floor nozzle 
Caution! When the water tank is filled, 
the appliance may only be operated in 
the horizontal position. Prior to moving 
the appliance into the upright position, 
the water tank must be drained. Other-
wise the floor can be damaged. 
Note
Should the mains fuse trip upon switching 
on the appliance, it could be due to the fact 
that other electronic devices are simultane-
ously connected and operated on the same 
electric circuit. Refer to chapter "Technical 
data" for mains fuse.
The appliance will shut down automatically 
if there is risk of overheating. Turn the ap-
pliance off and pull the power plug. Replace 
the HEPA filter. After the elimination of the 
disturbance, allow the appliance to cool 
down for a at least 1 hour; then the appli-
ance is ready for operation again.
Illustration 
Connect suction hose to the appliance.
Connect the handle to the telescopic vac-
uum pipe and attach the floor nozzle.
Illustration 
Activate the release and extend or re-
tract the interior pipe to the desired 
length.
Note: Adjust the telescoping pipe 
matching your height so that you will be 
able to work comfortably while walking 
upright.
Caution
Do not use the device if the water filter con-
tainer is empty!
When the appliance is delivered, the inter-
mediate filter and the baffle plate are al-
ready installed. When filling, make sure that 
these components are installed properly 
(see: SCOPE OF DELIVERY). This could 
be the cause of poor vacuuming perfor-
mance or untimely failure of the intermedi-
ate filter (see: FINISH OPERATION).
Illustration 
Open the appliance flap and remove 
the defoamer liquid (FoamStop) as well 
as the water filter container.
Illustration 
Remove the lid from the water filter con-
tainer and take out the baffle plate, then 
fill the water filter container with tap wa-
ter until the level settles between the 
MIN and MAX markings (approx. 1.7 l)!
Illustration 
Add one cap full of the defoaming liquid 
(FoamStop) to the water filter reservoir.
Note: The functioning of the vacuum 
cleaner is based on the whirling of the 
suction air in the water filter. In the pro-
cess, sucked-in materials and deposits 
of cleaning agents from floors get col-
lected in the water bath. This can some-
times lead to the formation of foam. It is 
necessary to add a capful of the de-
foamer liquid to the water bath to avoid 
this situation. Slight foam formation is 
normal and does not hamper the func-
tioning of the machine.
Illustration 
Note: Please refill water as soon as the 
water level in the reservoir sinks below 
the MIN mark.
Insert the baffle plate and reattach the 
lid of the water filter container. Install 
the complete water filter container in the 
appliance.
Commissioning/ Operations
Connect accessories
Fill the water filter reservoir
14