2
AC Power Cords for Cisco Aironet 1520 Series Outdoor Mesh Access Points
78-18268-02
  
When using a user-supplied AC power plug on the AIR-CORD-R3P-40UE= power cord, ensure that the 
plug is certified for outdoor use and that it has a minimum IP67 rating, such as Interpower 84131251 or 
Hubbell HBL316P6W (IEC/EN60309) pin-and-sleeve type connectors. The European Union power cord 
plug pinouts are listed in 
Figure 1
European Union Plug Pinouts
Caution
All AC power plugs and AC receptacles must be protected from water and other outdoor elements. Use 
a UL listed waterproofing enclosure suitable for covering the AC receptacle and AC power plug that 
supplies power to the unit as described in Article 406 of the NEC. If the power cord goes through a metal 
cover, install a bushing to prevent fraying of the cord.
When using a strain relief bushing, you should follow these recommendations:
Use properly sized parts (see 
 for the power cord diameter) 
Use bushings that are safety certified 
Use parts that are suitable for outdoor installation 
Caution
If your power cord does not use an AC power plug, you must ensure that the power source is OFF before 
connecting or disconnecting the power cord wires from the power source.
Warning
When installing or replacing the unit, the ground connection must always be made first and 
disconnected last. 
Statement 1046
Pin
Description
Conductor Color
Pin Description
Conductor Color
1
Ground
Green/Yellow
3
Neutral
Blue
2
Live
Brown
1
2
3