Cisco Cisco Aironet 350 Workgroup Bridges 릴리즈 노트

다운로드
페이지 10
F I R S T   D R A F T   -   C I S C O   C O N F I D E N T I A L
3
Release Notes for Cisco Aironet 350 Series Workgroup Bridges Running Firmware Release 8.89
OL-6341-01
  New Features
Step 10
Double-click WGB350v889.exe to expand the downloaded file, and record the location where you 
stored the expanded .img file.
Upgrading the Workgroup Bridge Firmware
Follow these steps to upgrade the workgroup bridge firmware image by using an Internet browser:
Step 1
Open an Internet browser on a computer that is on the same network as the bridge. 
Step 2
Enter the bridge IP address in the browserlocation field. Click Enter.
Step 3
When the bridge management home page appears, click Allow Config Changes in the upper-left corner.
Step 4
In the Diagnostics menu, click Load.
Step 5
Enter the path and filename of the new image file in the entry field, such as 
c:\firmware\WGB350v889.img.
Step 6
Click Send. The workgroup bridge loads the new firmware and reboots.
Step 7
If an error message appears stating that the page cannot be refreshed without resending the information, 
click Cancel. The workgroup bridge loads the new firmware, and you can ignore the message.
Step 8
To verify that the upgrade is successful, repeat 
Step 1
 and 
Step 2
. When the bridge management home 
page appears, verify that the new firmware version number (8.89) appears beside the model name in the 
upper-left corner of the page.
New Features
There are no new features in this software maintenance release.
Installation Notes
Verify Mounting Hole Measurement
If you make a photocopy of the mounting template (included in Mounting Instructions for the Cisco 
Aironet Access Points, Base Stations, and Workgroup Bridges with Plastic Cases), 
make sure that the 
distance between the holes is 4 3/4 in. (12.06 cm) before you drill the holes. Some photocopy machines 
do not make exact duplicates of the original.