Cisco Cisco Aironet 350 Access Points 릴리즈 노트
10
Release Notes for Cisco Aironet 340 and 350 Series Access Points and 350 Series Bridges Running VxWorks Firmware Version 12.03T
OL-4150-01
Caveats
•
CSCdy83165—Access points no longer lose connectivity.
•
CSCdx81372—The access point now accepts version 11.21-generated ini file.
•
CSCdz03100—340 series bridge links are now stable when you replace a 340 series bridge with a
350 series bridge.
350 series bridge.
•
CSCdz07823—An access point in hot standby mode no longer sporadically associates with its
parent access point.
parent access point.
•
CSCdz09445—Spanning Tree Protocol now works with MIC on 350 bridges.
•
CSCdz32962—Enabling MIC no longer causes immediate hot standby takeover by the standby unit.
•
CSCdz34132—Aironet Client Utility (ACU) now displays IP address with EAP-TLS instead of
MAC address.
MAC address.
•
CSCdz38726—Eliminated possible confusion for exiting console.
•
CSCdz41180—The Clear Alert Statistics button in the Event Handling Setup page is correctly
documented.
documented.
•
CSCdz47442—IP Setup Utility (IPSU) returns incorrect IP addresses in large networks.
This caveat is closed. Based on testing, the problem occurs only with old VxWorks or IOS software
releases. If a network has mixed access points with old and new software releases, the problem may
exist. Upgrading all access points to a new software release eliminates the problem.
releases. If a network has mixed access points with old and new software releases, the problem may
exist. Upgrading all access points to a new software release eliminates the problem.
•
CSCdz48575—The access point now defaults to No Action on loss of Ethernet.
•
CSCdz61465—Build process no longer fails with the latest IEEE MIB file version 6.2.
•
CSCdz67252—The access point no longer becomes unresponsive when issuing a Telnet :?
command.
command.
•
CSCdz77680—The 350 series bridge no longer fails when handling a large amount of traffic.
•
CSCea09515—VxWorks access points now provide three EAP retries.
•
CSCea27480—A partial configuration is no longer applied when an error in the ini file is
encountered.
encountered.
•
CSCea30474—The time zone can now be configured with SNTP enabled.
•
CSCea41998—The 350 series access point no longer disconnects when CDP is enabled.
•
CSCea45758—Documentation describing EAP authentication has been expanded and corrected.
•
CSCea66535—The hot standby feature now works with LEAP, TKIP, MIC, and Broadcast key
rotation.
rotation.
•
CSCeb18758—Documentation now better explains workgroup bridge limitations in network
infrastructure mode.
infrastructure mode.
See the
for more information.
•
CSCin46076—Client now gets DHCP IP address with EAP-MD5 and VLAN.