Eaton KIT-CABLRES-24 사용자 설명서

다운로드
페이지 23
www.epdu.com 1.800.356.5794
5
SPECIFICATIONS
IPC3400-A1
IPC3400-A1-NET
IPC3400-AB
IPC3400-AB-NET
Approvals
NA
NA
NA
NA
Voltage Input/Output (50/60Hz)
120V~
120V~
100-240V~
100-240V~
Current Input
15A
15A
15A
15A
Current Output
12A
12A
12A
12A
Full Load VA
1440 VA
1440 VA
1440 VA/2880 VA
1440 VA/2880 VA
NEMA Outlets (rear panel)
5-15R
5-15R
IEC 60320 Type C13
IEC 60320 Type C13
EMI/RFI Filter
15A
15A
15A
15A
Surge Suppression
270V
270V
270V
270V
Power Cord/Length (rear panel)
14/3, 9’
14/3, 9’
14/3, 8’
14/3, 8’
Power Input Plug
5-15P
5-15P
IEC 60320 Type C14
IEC 60320 Type C14
Serial Control (RS232)
YES
YES
YES
YES
Ethernet Control
NO
YES
NO
YES
TABLE TOP
•  Height 3.4” x Depth 7.5” x Width 5.75”  
•  Approximate shipping weight is 6 lb.
OUTLETS
•  IPC3400-A1 has 4 NEMA outlets
•  IPC3400-AB has 4 IEC outlets
(6) INDICATOR LIGHTS
•  (1) Main power
•  (1) Data light
•  (4) Power on to outlets 1-4
COMMUNICATIONS
•  RS232, Serial: 9600 baud only
•  Optional ethernet control via RJ45
 connector (add -NET to part number)
•  Data terminal emulation software is required
 to communicate with the IPC internal
 command codes such a Telnet or
 Hyperterminal
MODEM ACCESS
•  External modem must be put in auto-answer
 mode prior to making contact with the IPC
EMI/RFI FILTERING
•  Common Mode - line to ground
•  Differential Mode - line to line
• Refer to chart 2 on page 20
SPIKE/SURGE SUPPRESSION
•  L-N, L-G, N-G
• Refer to chart 1 on page 20
POWER INPUT
•  IEC C14 power inlet
•  Power cable included:
 -AB version has 8’ C13 to C14
 -A1 version has 9’ C13 to 5-15P
OUTLET STATUS
•  Query the IPC for Outlet and Watchdog  
 status, i.e. outlets are “on” or “off”
MULTIPLE TIME DELAY
TM
 (MTD
TM
)
•  Turn outlets “on” or “off” at one time
•  Sequence power up and power down to
 outlets 1 - 4 with a four second time delay
 (factory set)
•  Set power “on” sequence to any combination
 of outlets
•  Set the MTD
TM
timing from 1 second to
 999 seconds, i.e. 009 = 9 seconds
PASSWORD PROTECTION
•  For added security, a password feature  
 is included which allows the user to assign
 a three alphanumeric character password
ADDRESSING
•  The IPC comes with a default address  
 but you can also create your own with  
 any four alphanumeric characters
WATCH-DOG/AUTO-REBOOT
•  The IPC will monitor the control connection
 and automatically reboot itself if the
 connection locks up. The auto-reboot is  
 activated by the time-out period running
 down to zero. When this occurs the IPC will
 shut down all outlets for four seconds and
 restart in the default or user defined sequence
•  Set the Time Out Period to any number 0-9
 where each digit represents 30 seconds,
 i.e. 3 = 120 seconds (user defined)
COMMANDS AVAILABLE
•  All outlets on/off
•  Individual outlet on/off
•  Set up and Sequence on/off all outlets
•  Create password and unit address
•  Name outlets with 8 character name
•  Set up, enable or disable Watchdog
•  Display outlet and Watchdog Timer status
Intelligent Power Control
  
IPC3400 Series
120V~ or 240V~,15A, Single Phase, 50/60 Hz