SPECIFICATIONS
IPC3400-A1
IPC3400-A1-NET
IPC3400-AB
IPC3400-AB-NET
Approvals
NA
NA
NA
NA
Voltage Input/Output (50/60Hz)
120V~
120V~
100-240V~
100-240V~
Current Input
15A
15A
15A
15A
Current Output
12A
12A
12A
12A
Full Load VA
1440 VA
1440 VA
1440 VA/2880 VA
1440 VA/2880 VA
NEMA Outlets (rear panel)
5-15R
5-15R
IEC 60320 Type C13
IEC 60320 Type C13
EMI/RFI Filter
15A
15A
15A
15A
Surge Suppression
270V
270V
270V
270V
Power Cord/Length (rear panel)
14/3, 9’
14/3, 9’
14/3, 8’
14/3, 8’
Power Input Plug
5-15P
5-15P
IEC 60320 Type C14
IEC 60320 Type C14
Serial Control (RS232)
YES
YES
YES
YES
Ethernet Control
NO
YES
NO
YES
TABLE TOP
• Height 3.4” x Depth 7.5” x Width 5.75”
• Approximate shipping weight is 6 lb.
OUTLETS
• IPC3400-A1 has 4 NEMA outlets
• IPC3400-AB has 4 IEC outlets
(6) INDICATOR LIGHTS
• (1) Main power
• (1) Data light
• (4) Power on to outlets 1-4
COMMUNICATIONS
• RS232, Serial: 9600 baud only
• Optional ethernet control via RJ45
connector (add -NET to part number)
• Data terminal emulation software is required
to communicate with the IPC internal
command codes such a Telnet or
Hyperterminal
MODEM ACCESS
• External modem must be put in auto-answer
mode prior to making contact with the IPC
EMI/RFI FILTERING
• Common Mode - line to ground
• Differential Mode - line to line
• Refer to chart 2 on page 20
SPIKE/SURGE SUPPRESSION
• L-N, L-G, N-G
• Refer to chart 1 on page 20
POWER INPUT
• IEC C14 power inlet
• Power cable included:
-AB version has 8’ C13 to C14
-A1 version has 9’ C13 to 5-15P
OUTLET STATUS
• Query the IPC for Outlet and Watchdog
status, i.e. outlets are “on” or “off”
MULTIPLE TIME DELAY
TM
(MTD
TM
)
• Turn outlets “on” or “off” at one time
• Sequence power up and power down to
outlets 1 - 4 with a four second time delay
(factory set)
• Set power “on” sequence to any combination
of outlets
• Set the MTD
TM
timing from 1 second to
999 seconds, i.e. 009 = 9 seconds
PASSWORD PROTECTION
• For added security, a password feature
is included which allows the user to assign
a three alphanumeric character password
ADDRESSING
• The IPC comes with a default address
but you can also create your own with
any four alphanumeric characters
WATCH-DOG/AUTO-REBOOT
• The IPC will monitor the control connection
and automatically reboot itself if the
connection locks up. The auto-reboot is
activated by the time-out period running
down to zero. When this occurs the IPC will
shut down all outlets for four seconds and
restart in the default or user defined sequence
• Set the Time Out Period to any number 0-9
where each digit represents 30 seconds,
i.e. 3 = 120 seconds (user defined)
COMMANDS AVAILABLE
• All outlets on/off
• Individual outlet on/off
• Set up and Sequence on/off all outlets
• Create password and unit address
• Name outlets with 8 character name
• Set up, enable or disable Watchdog
• Display outlet and Watchdog Timer status
Intelligent Power Control
IPC3400 Series
120V~ or 240V~,15A, Single Phase, 50/60 Hz