Alliance Laundry Systems 1305 사용자 설명서

다운로드
페이지 111
Allen-Bradley 1336-Series AC Drives
85
F232120
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Interference
EMI
Careful attention must be given to the arrangement of 
power and ground connections to the drive to avoid 
interference with nearby sensitive equipment. Be sure 
to replace all ground connections to their appropriate 
locations.
RFI
Drives can be installed with an RFI filter, which 
controls high-frequency conducted emissions into the 
main supply lines.
Where it is essential that very low emission levels 
must be achieved or if conformity with standards is 
required, the optional RFI filter may be present. 
Figure 47 displays an electrical schematic for various 
RFI configurations. Table 47 shows associated RFI 
filter part numbers.
Figure 47 
CAUTION
ELECTRIC SHOCK HAZARD! Service and 
maintenance to be performed only by an 
authorized technician. Disconnect power 
before opening any access panels.
W661
U166ME3A
L1
TO AC DRIVE UNIT Ð
GREEN-YELLOW WIRE MUST CONNECT TO
AC DRIVE GROUND TERMINAL.
BLACK WIRES WILL CONNECT TO AC DRIVE
INPUT TERMINALS "R", "S" & "T".
BLACK WIRES ARE  NOT LABELED AND THEIR
RESPECTIVE TERMINATION IN AC DRIVE IS
NOT OF IMPORTANCE.
L2
ALLEN-BRADLEY
RFI
FILTER
L3
LINE
LOAD
PROVEN EARTH GROUND
WASHING
MACHINE
GROUNDING
TERMINAL
THREE PHASE MACHINES
INPUT
POWER
1 2
3
2
3
L1
TO AC DRIVE UNIT Ð
GREEN-YELLOW WIRE MUST CONNECT TO
AC DRIVE GROUND TERMINAL.
BLACK WIRES WILL CONNECT TO AC DRIVE
INPUT TERMINALS "R", "S" & "T".
BLACK WIRES ARE  NOT LABELED AND THEIR
RESPECTIVE TERMINATION IN AC DRIVE IS
NOT OF IMPORTANCE.
L2
ALLEN-BRADLEY
RFI
FILTER
LINE
LOAD
PROVEN EARTH GROUND
WASHING
MACHINE
GROUNDING
TERMINAL
SINGLE PHASE MACHINES
INPUT
POWER
1 2
3
2
3
U166ME3A
RFI Filter Part Number Information
Drive P/N
Drive Catalog
Machine Voltage
Filter P/N
370838
1336-AQF50
200-240V/1 Phase
Not Available
370838
1336-AQF50
200-240V/3 Phase
330274
370835
1336-BRF50
380-480V/3 Phase
330273
370837
1336-AQF100
200-240V/3 Phase
Not Available
370834
1336-BRF100
380-480V/3 Phase
330274
370828
1336-AO15
200-240V/3 Phase
330268
370825
1336-BO25
380-480V/3 Phase
330268
Table 47