Power Terminal Block Description
Input and output connections are performed through 
terminal block TB1. Refer to Figure 49.
Figure 49 
Power Block Terminal (TB1)
Torque Specifications
GRD GRD
R
(L1)
S
(L2)
T
(L3)
DC
+
DC
-
U
(T1)
V
(T2)
W
(T3)
To
Motor
To Motor
Protected AC Input
200-240V, 0.37 Ð 3.7 kW (0.5 Ð 5 HP) Terminal Designations
380-480V, 0.37 Ð 3.7 kW (7.5 Ð 10 HP) Terminal Designations
   
A1-A3 
Frame
U083ME3A
DC
-
COM
BRK
-
Dynamic Brake
2
DC
Input Line
GRD GRD
R
(L1)
S
(L2)
T
(L3)
DC
+
U
(T1)
V
(T2)
W
(T3)
To
Motor
To Motor
Protected
AC Input
380-480V, 5.5 Ð 7.5 kW (7.5 Ð 10 HP) Terminal Designations
A4 
Frame
U084ME3A
Dynamic Brake
PE
PE
R
(L1)
S
(L2)
T
(L3)
DC
+
DC
-
U
(T1)
V
(T2)
W
(T3)
To
Motor
To Motor
Protected
AC Input
200-240V, 5.5 kW (7.5 HP) Terminal Designations
380-480V/500-600V, 5.5 Ð 11 kW (7.5 Ð 15 HP) Terminal Designations
B1 
Frame
U085ME3A
B2 
Frame
Dynamic Brake
To
Motor
To Motor
Protected
AC Input
PE
PE
R
(L1)
S
(L2)
T
(L3)
DC
+
DC
-
U
(T1)
V
(T2)
W
(T3)
200-240V, 7.5 Ð 11 kW (10 Ð 15 HP) Terminal Designations
380-480V, 15 Ð 22 kW (20 Ð 30 HP) Terminal Designations
U086ME3A
Terminal
Description
PE
Potential Earth Ground
R (L1), S (L2), T (L3) 
AC Line Input Terminals
+DC, -DC
DC Bus Terminals
U (T1), V (T2), W (T3)
Motor Connection
Table 48 
Drive 
Frame 
Size
Max./Min. Wire 
Size* 
mm
(AWG)
Maximum Torque 
N-m (lb.-in.)
A1-A4
5.3/0.8 
(10/18)
1.81 
(16)
B1
8.4/0.8 
(8/18)
1.81 
(16)
B2
13.3/0.5 
(6/20)
1.70 
(15)
*
Wire sizes given are maximum/minimum sizes that TB1 will accept –
these are not recommendations.
Table 49