National Instruments DIO 6533 사용자 설명서

다운로드
페이지 125
Chapter 5
Signal Timing
DIO 6533 User Manual
5-2
© National Instruments Corporation
Request Timing
Internal Requests
Figure 5-2 shows internal request timing. You can select a timebase and 
an interval. The request pulses low once per data transfer. The duration 
of the low pulse is equal to one timebase. The period of the request 
pulse is equal to the interval multiplied by the timebase (in LabVIEW, 
you specify an overall period, and the software selects the interval and 
timebase).
Figure 5-2.  Internal Request Timing
External Requests
 shows external request timing. The request signal must pulse 
low and return high. The request pulse low and high durations must be 
at least 20 ns each. The minimum period is 50 ns.
Parameter Description
t
c
Cycle time
t
lw
Width of low pulse
t
p
Propagation time to valid output data
t
su
Setup time
t
h
Hold time
Data (Output Mode)
Data (Input Mode)
REQ
th
tsu
30 ns
Min
0 ns
Min
tp
30 ns
Max
tlw
Programmable = One Timebase
tc
Programmable = Interval x Timebase