Simon Security System
16
5.
Plug the universal module into a wall outlet.
Sensor Installation
Program sensors and devices before you install them. Use the following section to pro-
gram the panel and add the sensors to panel memory.
Programming
Entering Program Mode
There are 2 codes you can use to enter program mode.
Utility Access Code 1 (Dealer Code)
Depending upon how Option 54 is set, the default utility access code is 654321, 
54321, 4321 (factory default), or 321. This code can be used for all programming.
Utility Access Code 2 (Installer Code)
Depending upon how Option 54 is set, the default access code is 654321, 54321, 4321 
(factory default), or 321. This code is limited to changing all but the following: Utility 
Access Code 1, Options 4, 5, 6, 8, 9, 12, 13, 54, and 69.
1.
Open the panel cover.
2.
Enter Utility Access Code 1 or 2 using the numbered keys.
Note  
Do not remove panel power 
while in program mode. Pro-
gramming changes are 
saved only when exiting pro-
gram mode (closing the 
panel cover).
The panel is now in program mode. Follow the programming arrows on the panel 
label. The system prompts you through programming steps with beeps and voice mes-
sages.
¾
Program the panel in this order:
1.
Set the panel clock.
2.
Add (learn) sensors.
3.
Set House Code and Light & Appliance Controls (Entry/Exit activated lights, 
Sensor activated lights, Time activated lights).
4.
Change numbered Options as needed.
Exiting Program Mode
Close the cover to exit program mode when you are finished programming.
Reset Memory to the Factory Defaults
Note  
If Option 8: Phone Lock is 
on, options 04, 05, 06, 08, 
09, 12, 13, 54 and Dealer 
Code will not reset to their 
defaults.
1.
Open the panel cover and enter Utility Access code 1.
2.
Unplug the transformer and disconnect the battery.
3.
Simultaneously press and hold CancelClock Set, and 
Minutes +.
4.
Restore power to the panel with either the battery or the transformer while press-
ing these three buttons. The panel announces “Hello. System XX OK.” Release 
the buttons.
5.
Connect the remaining power source to the panel.
Set the Clock
1.
Press Clock Set from the Start Menu.
2.
Press the Hours + and 
– 
keys and listen to the voice prompts. Stop when panel 
voice announces the correct hour.
3.
Press the Minutes + and 
– 
keys and listen to the voice prompts. Stop when the 
panel announces the correct minutes.
Do not power down the panel while in program mode or all programming will be 
lost. The panel stores programmed information only when you exit program 
!
mode (close the cover and leave closed for at least 5 seconds).
Caution
!