ge-interlogix simon 3 사용자 설명서

다운로드
페이지 68
Simon Security System
22
Note  
Pressing DONE is required if 
you enter fewer than 26 dig-
its. The phone number is 
automatically stored without 
pressing DONE if all 26 
places are used.
¾
To set Downloader Phone Number, press:
Add—Option #—06—Up to 26 digits—DONE.
¾
To delete Downloader Phone Number, press:
Delete—Option #—06—DONE.
Option 07: Account Number (Default = 00000)
Note  
The CID format only sup-
ports account numbers with 
letters B through F, or num-
bers 0 through 9 (or a com-
bination of those letters and 
numbers).
Lets you program up to a 10-character alphanumeric account number (on) or delete an 
existing account number (off).
To enter letters (A - F only), press 9 then the Minutes + button. The panel announces 
the letter A. Continue pressing the Minutes + button to progress through the alphabet.
Note  
Pressing DONE is required if 
you enter fewer than 10 
characters. The account 
number is automatically 
stored without pressing 
DONE if 11 characters are 
entered, of which only the 
first 10 are stored.
¾
To set Account Number, press:
Add—Option #—07—Up to 10 characters—DONE.
¾
To delete Account Number, press:
Delete—Option #—07—DONE.
Option 08: Phone Lock (Default = off)
Prevents resetting of phone/reporting related Options 04, 05, 06, 08, 09, 12, 13, 54 and 
Utility Code when a memory clear is performed (on), or resets these options to their 
default values when a memory clear is performed (off).
¾
To turn on Phone Lock, press:
Add—Option #—08—DONE.
¾
To turn off Phone Lock, press:
Delete—Option #—08—DONE.
Option 09: Downloader Code (Default = 12345)
Lets you set a unique 5-digit code that is required for initiating ToolBox sessions (on) 
or sets the code to its default (off).
The code must be 5 digits long and can range from 00000 to 99999. The Downloader 
Code must match the downloader access code in the ToolBox account to perform 
ToolBox sessions.
Note  
The downloader code 
should always be changed 
from the default setting to 
avoid competitor theft.
¾
To set Downloader Code, press:
Add—Option #—09—5-digit code—DONE.
¾
To delete Downloader Code (return to default), press:
Delete—Option #—09—DONE.
Option 10: Entry Delay (Default = 030 sec)
Determines how much time the user has to disarm the system after entering the armed 
premises through a designated delay door, before an alarm occurs. Beeps sound during 
the entire delay time to remind the user to disarm the system.
When turned on, the Entry Delay can be set from 005-254 seconds (030-254 if SIA 
Limits Option 69 is on). All entries must be 3 digits. When turned off, the Entry Delay 
is set to 005 seconds.
Note  
For UL listed systems, the 
entry delay must not exceed 
45 seconds.
¾
To set Entry Delay, press:
Add—Option #—10—3-digit delay time—DONE.
¾
To reset Entry Delay (return to default), press:
Delete—Option #—10—DONE.