ge-interlogix simon 3 사용자 설명서

다운로드
페이지 68
Simon Security System
20
The “Numbered Options” table in Appendix B lists all system options and their char-
acteristics. Fill in the last column of the table before programming to help speed up the 
programming process.
Note  
Although the panel voice 
prompts you through pro-
gramming, it is not neces-
sary to wait for the complete 
message before pressing 
the next button in the pro-
gramming sequence.
There are two ways to reach the desired option setting.
Press Add or Delete, then press Option # repeatedly until you hear the option you 
want changed.
Or—
Press Add or DeleteOption #, then enter the option number using the numbered 
keys.
The following instructions use the last method.
Option 01: Panel Piezo Beeps (Default = On)
Determines whether the panel piezo produces beeps based on system activity (on) or is 
silent (off). The following table describes all possible beeps.
Note  
For all UL listed systems, 
Option 1 must be on 
(added).
¾
To turn on Panel Piezo Beeps, press:
Add—Option #—01—DONE.
¾
To turn off Panel Piezo Beeps, press:
Delete—Option #—01—DONE.
Panel Piezo Beeps
Activity
Piezo Beep Response
ARM Doors & Windows
Exit Delay—2 beeps sound every 5 seconds and 2 
times per second during the last 10 seconds.
Silent Exit—2 beeps sound at the beginning of the 
exit delay and 2 more sound just before the exit 
delay expires.
Entry Delay—2 beeps sound every 5 seconds and 2 
times per second during the last 10 seconds.
ARM Motion Sensors
Exit Delay—3 beeps sound every 5 seconds and 3 
times per second during the last 10 seconds.
Silent Exit—3 beeps sound at the beginning of the 
exit delay and 3 more sound just before the exit 
delay expires.
Entry Delay—3 beeps sound every 5 seconds and 3 
times per second during the last 10 seconds.
ARM Doors/Windows & 
Motion Sensors
Exit Delay—4 beeps sound every 5 seconds and 4 
times per second during the last 10 seconds.
Silent Exit—4 beeps sound at the beginning of the 
exit delay and 4 more sound just before the exit 
delay expires.
Entry Delay—4 beeps sound every 5 seconds and 4 
times per second during the last 10 seconds.
DISARM
1 beep
CHIME DOORS 
2 beeps (when programmed)
CHIME SPECIAL MOTION
3 beeps (when programmed)
Trouble Beeps
6 beeps every minute. Press SYSTEM STATUS to 
stop beeps for 4 hours.
No Activity
20 beeps every minute for 5 minutes (when pro-
grammed)