ge-interlogix simon 3 사용자 설명서

다운로드
페이지 68
Simon Security System
42
DISARM -The panel will prompt you to enter an access code. Enter the appropri-
ate code and the panel will disarm Doors, Windows, and Motion Sensors.
No beeps verify sub-disarms (LED blinks).
One beep indicates the system is disarmed
Two beeps verify that Door/Window sensors are armed.
Three beeps verify that Motion Sensors are armed.
Four beeps verify that both Door/Window and Motion sensors are armed.
SYSTEM STATUS-Press to determine system status and system time.
CHIME Doors-Press to enable two beeps that sound from interior sirens, panel 
siren, and the X10 powerhorn siren (if set to unit number 9) when a protected door 
or window learned into sensor group 10 or 13 is opened. If Option 41: Chime 
Voice is on, the panel speaker also announces the sensor name and number.
CHIME Special Motion- Press to enable three beeps that sound from interior 
sirens, panel siren, and the X10 powerhorn siren (if set to unit number 9) when a 
Motion Sensor that is programmed as sensor type 25 is activated. If there are no 
sensors learned into sensor group 25, this function will not be available. If Option 
41: Chime Voice is on, the panel speaker also announces the sensor name and 
number.
LIGHTS Time Activated-Press to enable system controlled lights to turn on/off at 
a scheduled time.
LIGHTS Sensor Activated-Press to enable system controlled lights to turn on for 
4 minutes when a specific sensor is tripped.
AUX, POLICE, FIRE-Press and hold or press twice quickly to activate a non-
medical, police, or fire emergency alarm
Sensor Testing
We recommend that you test the sensors after all programming is completed and 
whenever a sensor-related problem occurs.
Note  
While the sensor test is a 
valuable installation and ser-
vice tool, it only tests sensor 
operation for the current 
conditions. You should per-
form a sensor test after any 
change in environment, 
equipment, or programming.
1.
Place all sensors in their secured (non-alarm) state.
2.
Open the panel cover. 
3.
Enter the appropriate access code.
4.
Press Test.
The panel responds with Sensor test, press again to change or DONE to select.
5.
Press DONE.
Arming Levels
Arming Level
Description of Level
0
Sub-disarms (Master Access and Panic codes only), 
and bypasses 24 hour intrusion sensors (Master 
Access Code only). Fire sensors (group 26) cannot be 
sub-disarmed.
1
Disarm the system
2
Arm Doors and Windows
3
Arm Motions
4
Arm Doors, Windows, and Motions