MC-Series High-Power System 
 
System Configuration Changes 
998--01 Rev X1 
RadioFrame Networks, Inc. 
CONFIDENTIAL AND PROPRIETARY 115 
 
 
Table 39  Handover and Reselection Test Worksheet 
Test # 
Handover (Mobile #) 
Carrier # from (HEX) 
Carrier # to (HEX) 
1  
 
 
2  
 
 
3  
 
 
 
Cell Reselection (Mobile #) 
 
 
1  
 
 
2  
 
 
3  
 
 
D.5 Interconnect Connection Stability and SQE Performance 
A single link for 3:1 Interconnect should be maintained for 30 minutes each. Table 40 
presents the data to be collected for each selected link. The iDEN Field Test Application 
(IFTA) is be used in “Single Cell” mode to observe the SQE performance and plotted over 
time. 
Table 40  Interconnect Connection Stability Worksheet 
Interconnect #1 
Carrier # 
RSSI (dBm) 
SQE (dB) 
Sector 
Duration (min) 
  
 
 
 
30 
Interconnect #2 
 
 
 
 
 
  
 
 
 
30 
Interconnect #3 
 
 
 
 
 
 
 
 
 
 
 
D.6 Dispatch Connection Stability 
To verify Dispatch connection stability, a Dispatch (private or group) call should be 
maintained for several minutes. Table 41 presents the data to be collected for each 
dispatch call. 
Table 41  Dispatch Connection Stability Worksheet 
Dispatch #1 
Carrier # 
RSSI (dB) 
SQE (dB) 
Sector 
Quality (1-
5) 
Duration (min) 
 
 
 
 
 
 
Dispatch #2 
 
 
 
 
 
 
 
 
 
 
 
 
Dispatch #3 
 
 
 
 
 
 
 
 
 
 
 
 
D.7 
Idle SQE Testing and Validation
 
Using the iFTA tool in “Single Cell” mode, record the idle RSSI and SQE values for the 
control channel for at least one hour per sector, while the mobile remains fixed.  
Then, conduct the same procedure while walking the facility for approximately 15 
minutes.