사용자 설명서차례1 Introduction101.1 References101.2 General Safety Information101.2.1 Static Sensitive Precautions101.2.2 Safety Warnings111.2.2.1 Safety Warnings per Rack Mount Instructions111.2.3 Recommendations121.3 Repair and Technical Support121.3.1 Technical Support131.3.2 Field Replaceable Unit (FRU) Policy132 System Definition142.1 MC-Series High Power System Configuration162.2 RadioFrame Networks Hardware192.2.1 Air/BTS Interface Chassis (ABIC)192.2.1.1 BIC CRIC202.2.1.2 BPC202.2.1.3 ERTM202.2.1.4 CRTC202.2.1.5 BIC Ports212.2.1.6 BIC Indicators212.2.2 Airlink Interface Chassis (AIC)222.2.2.1 AIC CRIC222.2.2.2 BPC+SPAM222.2.2.3 ERTM222.2.3 RadioBlade Shelf (RBS)222.2.3.1 RBS Ports242.2.3.2 RBS Indicators242.2.4 iDEN RadioBlade Transceivers242.2.4.1 800 MHz RadioBlade Transceivers252.2.4.2 Multi-Channel RadioBlade Transceivers252.2.4.3 Combined RadioBlade Transceivers in an RBS262.2.5 High Power Dual-Band RF Shelf262.2.6 Power Distribution Unit272.2.7 Cabinet282.3 System Manager Software282.4 Non-RFN Hardware292.4.1 integrated Site Controller (iSC-3) (comes pre-installed)292.4.2 Environmental Alarm System (EAS) (comes pre-installed)292.4.3 Channel Service Unit (CSU) (must be installed)312.4.4 GPS Antenna System (must be installed)312.4.5 Powerplant (must be installed)312.5 Specifications322.5.1 Dimensions322.5.2 Weight332.5.3 Floor Loading332.5.4 Power Requirements332.5.5 Power Consumption342.5.6 Grounding342.5.7 Heat Load342.5.8 RF Performance342.5.8.1 Operating Frequency Bands352.5.8.2 Transmitter Performance Summary352.5.8.3 Tx Power Out352.5.8.4 Receiver Performance Summary362.5.8.5 Spurious RF Emissions362.5.9 Environmental Specifications372.5.10 Compliance37Pre-Installation373.1 Site Planning373.1.1 Space Requirements383.1.2 Floor Loading383.1.3 Anchoring383.1.4 Seismic Zone Installation383.1.5 Cooling of Equipment383.1.6 Power393.1.7 Grounding393.1.8 GPS Antennas393.1.9 T1 Service393.1.10 Alarm Blocks403.1.10.1 Environmental Alarm System (EAS)403.2 Scheduling / Logistics403.3 MC-Series High-Power System Installation Kit413.4 iDEN Configuration413.4.1 Cabinet and Position Settings413.4.2 BRs413.4.3 Sectorization42Installation424.1 Site Inspection424.2 Receipt of Equipment424.2.1 Equipment Inspection434.2.2 Equipment Inventory434.3 Mounting the MC-Series High-Power System Cabinet434.3.1 iSC-3s454.3.2 EAS464.3.3 CSU474.4 Mounting Auxiliary Equipment474.5 Cabinet-to-Site Cabling474.5.1 Grounding484.5.2 T1484.5.3 GPS Surge Arrestor484.5.4 EAS Alarm Cabling494.5.5 RF (Tx / Rx / Rx diversity)494.5.6 Power49Final Checkout and Commissioning495.1 Prerequisites505.2 Checkout Procedures515.3 Initial Powering Procedure515.4 System Setup525.5 Functionality Test56Management—Datafill, Configuration and Optimization576.1 Datafill576.1.1 Unsupported Datafill Parameters576.1.1.1 steThresholdMode576.1.1.2 brPwrReducModeAcg576.1.2 Parameters that Do Not Apply to the MC-Series High-Power System576.1.2.1 combinerType586.1.3 Recommended Datafill Parameters586.1.3.1 PCC586.1.3.2 Pto (transmit power)586.1.4 rxTxGain = 0586.1.4.1 defaultTxPower586.2 System Manager, Configuration and Optimization596.2.1 Navigating System Manager596.2.1.1 Logging into System Manager596.2.1.2 Changing the System Password606.2.2 Configuring the MC-Series High-Power System616.2.2.1 Navigating the System Configuration616.2.2.2 Viewing the Status of the RadioBlade Transceivers626.2.2.3 Locking and Unlocking a RadioBlade Transceiver646.2.2.4 RadioBlade Alarms Page656.2.2.5 Changing the Device Name, IP Address or Building Location666.2.2.6 Viewing Hardware and Software Versions676.2.2.7 Changing the iDEN Configuration686.2.3 Optimization Procedures696.2.3.1 Local Performance Monitoring696.2.3.2 iDEN Uplink Analysis716.2.3.3 Voice Loopback Diagnostic Test726.2.3.4 System Parameter Information Page737 Scheduled and Unscheduled Maintenance757.1 Maintenance757.2 Annual Maintenance757.3 Troubleshooting Guidelines757.4 Fault Indications757.4.1 BIC767.4.3 RBS777.4.4 RF Shelf777.5 System Manager Alarms787.5.1 Viewing System Manager Alarms787.5.2 OMC Alarm Code807.5.3 System Manager Alarms817.6 RadioBlade Transceiver Alarm Handling817.6.1 RadioBlade Locking Policy827.6.1.1 Standby Blade827.6.1.2 Locking Policy for RadioBlade Transceiver with Errors837.6.1.3 Removal of RadioBlade Transceiver837.6.1.4 Administrative Locking of a RadioBlade Transceiver837.7 Serial Log Upload Procedure857.8 Power Down Procedure867.9 Field Replaceable Unit (FRU) Procedures877.9.1 RF Shelf877.9.2 Replacing a Chassis: BIC, AIC or RBS877.9.2.1 BIC877.9.3 BIC/AIC– FRU Replacement Procedure877.9.3.1 Replacing the CRIC (BIC or AIC)877.9.3.2 BPC (BIC) or BPC+SPAM (AIC)897.9.3.3 ERTM907.9.3.4 CRTC917.9.4 RadioBlade Transceiver Replacement927.9.5 Power Distribution Unit948 System Configuration Changes978.1 Upgrading MC-Series System Software978.1.1 Download MC-Series System Software to the Laptop Computer978.1.2 Download FTP Server Software to the Laptop Computer978.1.2.1 Windows XP Method978.1.2.2 Windows 2000 Method988.1.3 Install the MC-Series System Software Update1018.1.4 Verify the Software Download1048.1.5 Reverting to the previous version of software1058.2 Performing a System Reset1058.3 Adding or Removing RadioBlade Transceivers1068.4 Field Replaceable Units (FRUs), Parts and Extra Supplies1068.4.1 Matching Terminals for PDU and Ground1068.4.2 GPS surge arrestor1078.4.3 RF Feed-Throughs (N-type connectors)107Appendix A. Definitions and Abbreviations108Appendix B. IP Address Requirements110Appendix C. High-Power iDEN Microcell Rack Stack-Up, 3-Sector (Default) Configuration111Appendix D. Functionality Test Procedures112D.1 Interconnect and Dispatch Setup and Voice Quality Testing112D.2 Packet Data Service Connection and Latency113D.3 Short Message Service114D.4 Handover and Cell Reselection114D.5 Interconnect Connection Stability and SQE Performance115D.6 Dispatch Connection Stability115D.7 Idle SQE Testing and Validation115D.8 System Self-Recovery Test116D.9 Packet Data Stability and Throughput116D.10 Validation of 'Unable to Key BR' Alarm116Appendix E. Tx / Rx Curves117Appendix F. BER Test Procedure119F.1 Prerequisites for Testing119F.2 Test Tool119F.3 Testing Strategy119F.4 Equipment Connection/Setup120F.5 BER Test Procedure121F.6 Equipment Disconnection127F.7 BER Test Notes Master127Appendix G. Dangerous RF Emissions Precautions129Figure 1 The MC-Series High-Power System15Figure 2 MC-Series High Power System 3-Sector Configuration18Figure 3 MC-Series High Power System Functional Diagram19Figure 4 ABIC Front View19Figure 5 ABIC Rear View, Showing Optional 2nd CRTC in the Third Slot19Figure 6 BIC CRIC Ports and Indicators20Figure 7 BPC indicators20Figure 8 ERTM Ports and Indicators20Figure 9 CRTC Ports and Indicators21Figure 10 BIC RJ-45 Port Indicators22BPC+SPAM Indicators22ERTM Ports and Indicators22RBS Group Functional Diagram23RBS Interior, Top Down View23RBS Front View23RBS Rear View24iDEN 2-Port RadioBlade Transceiver25MCRB Label Position26Dual-Band High Power RF Shelf Functional Diagram27Dual-Band High-Power RF Shelf Front View27Dual-Band High-Power RF Shelf Rear View27PDU Front View27PDU Rear View28System Manager Main Page29Punch Block Location within the MC-Series Rack31Locations of Non-RFN Hardware in MC-Series High-Power System Rack44Connections between the Primary iSC and BIC46Connection between EAS Control Port and PDU Status Connectors46Top of the Rack (TOR), Dual-Band Bulkhead, Cabling and Equipment48Location of RBS Side Rail Locking Arms52Location of BIC CRIC Laptop Connection Port53System Manager Welcome Screen54System Manager Log-in Window54iDEN Configuration Page55System Manager Home Page59Network Password Pop-up Dialog Box60Set System Manager Password Dialog Box60BIC Configuration Page Showing AIC, BIC and RBS Status61RadioBlade Status Page63RadioBlade Control Page65RadioBlade Alarms Page66System Configuration Page, BIC Selected Component67Software Version Information Page68iDEN Configuration Page69Operational Status—Performance Monitoring Page70Base Radio Performance Statistics Page71Uplink Analyzer Page72Voice Loopback Diagnostic Test Page73System Parameter Information Page74Alarm Log Page79System Lock All / Unlock All Feature84Serial Log Upload Link, Diagnostics Tab85Serial Log Upload Page with IP Address Prompt86RF Shelf Front View87RF Shelf Rear View87Replacing the CRIC in the BIC or AIC88Replacing the BPC in the BIC or the BPC+SPAM in the AIC89Rear of BIC (ERTM and CRTC) and AIC (ERTM Only)91Front View of the RadioBlade Shelf (RBS)93RadioBlade Transceiver in Place93Seating the RadioBlade Transceiver94RF Shelf Showing Side-Rail Locking Arm Locations94PDU, High-Power Rear View95PDU, High-Power Front View95Executing Wftpd from the Windows XP Laptop Run Dialog Box98Executing Wftpd from the Windows 2000 Laptop Run Dialog Box98Wftptd Settings (Bottom of Screen Shot)99General Security Dialog Box Settings99User / Rights Security Dialog Box Settings100New-User Name100Password101User Name Set in User/Rights Security Dialog Box101Download and Reset Links103Software Version Information Page105PolyPhaser RGT Broadband DC Pass Protector107800E Band Transmit Filter Frequency Response117900 MHz Transmit Filter Frequency Response117800E Band Rx Filter Response118900 MHz Band Rx Filter Response118BER Test Flow120RadioBlade Control Page122System Diagnostics Page124Bit Error Rate Test Page125Bit Error Rate Start Test Page126Table 1 FRU Table14Table 2 Sectorization and Maximum BR Allocation16Table 3 Ports in the BIC21Table 4 RBS Ports24Table 5 RBS Indicator LEDs24Table 6 PDU Circuit Breaker Overview27Table 7 MC-Series High-Power System Dimensions32Table 8 Weight33Table 9 Floor Loading33Table 10 Power Requirements33Table 11 Power Consumption per Assembly (See Note)34Table 12 Grounding Resistance at Cabinet (TOR)(See Note)34Table 13 Heat Load34Table 14 Transmit and Receive Frequencies35Table 15 Transmitter Performance Summary35Table 16 TOR Output Power36Table 17 Receiver Performance Summary36Table 18 Environmental Specifications37Table 19 Agency Compliances37Table 20 Installation Kit Materials List41Table 21 Status Color Interpretations62Table 22 BIC LED Indications76RBS LED Indications77RF Shelf LED Indications77Alarm Log Fields79Alarm Details Fields80Alarm Code 35009 Properties80Faults Tracked by the Transceiver81RadioBlade Transceiver Fault Thresholds for Alarm Generation82Power and Ground Lugs106Surge Arrestor Specifications107Specifications for N-Type Feed-Through Connectors107Address and Port Numbers for Chassis Boards110Interconnect Call Quality, Setup and Stability112Group Dispatch Call Quality, Setup and Stability112Private Dispatch Call Quality, Setup and Stability113Packet Data Latency over the MC-Series System (Ping –n 100 –w 2000 xx.xxx.xxx.x )113Packet Data Latency over Motorola EBTS114Handover and Reselection Test Worksheet115Interconnect Connection Stability Worksheet115Dispatch Connection Stability Worksheet115“Unable to Key BR” Alarm Severity Indications116BER Test Notes Master128크기: 2.48메가바이트페이지: 131Language: English매뉴얼 열기