MC-Series High-Power System 
 
System Configuration Changes 
998--01 Rev X1 
RadioFrame Networks, Inc. 
CONFIDENTIAL AND PROPRIETARY 127 
 
 
9  Verify that the displayed Rx Frequency matches the desired receive frequency.  
10 Approximately every second, the page reports the current BER measurement 
(
BER) and the running average of the ten latest BER measurements (BER Avg). 
Record these results, and then select the 
Stop Test button. 
Note:  If the warning “Test Signal Timing Out of Lock” appears, cycle power to the R2660 
and set it up again to generate an in-bound 1x6 test signal at the desired frequency 
and signal level into the Rx port. It may take a few minutes for the R2660 test signal 
to stabilize.  
Note:  If the only BER measurements reported are 50%, NO DATA, or both, verify that all 
procedure steps have been completed. If no problems are found, cycle power to the 
R2660 and set it up again to generate an in-bound 1x6 test signal at the desired 
frequency and signal level into the Rx port. It may take a few minutes for the R2660 
test signal to stabilize. If there's still no change after cycling power to the R2660, 
select the Stop Test button. 
11 When the BER test is complete, lock the RadioBlade transceiver that was under 
test. 
12 Display the RadioBlade Control page, and lock the RadioBlade transceiver by 
selecting its lock icon so that it is closed (locked). Refresh the page every 30 
seconds until the 
State of the RadioBlade transceiver has changed to ‘2’. 
13 Repeat Steps 1 through 11 for each RadioBlade transceiver to be tested on this Rx 
port. 
14 Move the test leads to the next sector at TOR when all desired blades in the current 
sector have been tested and repeat the procedure. 
F.6 Equipment Disconnection 
Disconnect equipment after completing the BER testing. 
1  Disconnect the R2660 from the Rx port under test. 
2  Display the RBS Status page, and verify that all RadioBlade transceiver status 
icons are green.  
3  Disconnect the network cable from port 8 of the BIC CRIC. 
F.7 BER Test Notes Master 
You can use this page to make copies of Table 43 for use as a handy organizer and 
permanent record of the BER tests.