Installation  
MC-Series High-Power System 
  
998--01 
Rev 
X1 
48 
CONFIDENTIAL AND PROPRIETARY 
RadioFrame Networks, Inc. 
 
TRADE SECRET INFORMATION 
•  RF (Tx / Rx / Rx diversity) 
• Power 
Figure 29  Top of the Rack (TOR), Dual-Band Bulkhead, Cabling and Equipment 
 
4.5.1  Grounding 
1  Ground the cabinet ground bar to the site according to Sprint Nextel’s installation 
instructions using 2-hole terminal lug. Type is Panduit 2-hole, P/N LCD6-14A, or 
equivalent. Required crimp tool is CT-1700. 
2  Connect the site ground to the ground at the top of the rack according to Sprint 
Nextel’s installation procedures (see Figure 29 for ground location at the top of the 
rack). 
4.5.2  T1 
1  Follow Sprint Nextel procedure for routing the site T1 cable through the top of the 
cabinet as shown in Figure 29. 
2  Connect the T1 cable to the CSU according to Sprint Nextel’s installation 
instructions. 
4.5.3  GPS Surge Arrestor 
Follow Sprint Nextel’s procedure for installing GPS equipment at the site. Then complete 
the following procedure: 
3  Install the two RFN-provided GPS surge arrestors at the top of the rack (Figure 29).