Installing the RadioFrame System 
 
15 
 
Figure 7 
Connect each RJ45 port on the back of the NCU to the associated 
ACU.  
Install the ACUs 
The method used to mount an Airlink Chassis Unit (ACU) is the same as for an 
NCU. Typically, mount an ACU, then install all the RFUs associated with that 
ACU by completing the procedure “Install the RFUs” next in this guide. Repeat 
the procedures “Install the ACU” and “Install the RFUs” for each ACU 
installation.  
Unpack and mount the Airlink Chassis Unit (ACU) 
Find these items in the ACU shipping container: one ACU, four mounting 
screws, and one 120VAC power cord. 
Mount the ACU only in an EIA-standard compliant (19”) rack using all 4 screws 
provided. Refer to the SDS for the exact location of the ACU. For safe operation, 
follow these guidelines: 
•  Do not mount the ACU in any orientation other than that specified in the 
following illustration. 
•  Mount the ACU so that both the front and the back are accessible.