RadioFrame Networks Inc RFU7 사용자 설명서
Installing the RadioFrame System
16
• If the mounting holes do not line up, adjust the ACU up or down until the
mounting holes line up.
Caution
Do not block the air vents on the sides or rear of the ACU.
3
Plug the ACU into an approved power source (for more information refer to
“Hardware Specifications”).
“Hardware Specifications”).
4
Verify that the ACU is receiving power and that each ACU card is operational.
Each card installed in the front and back of the ACU has two LEDs: Power and
Status. All LEDs should light green. If any LEDs do not light or are red, refer to
“Troubleshooting.”
Each card installed in the front and back of the ACU has two LEDs: Power and
Status. All LEDs should light green. If any LEDs do not light or are red, refer to
“Troubleshooting.”
Figure 8
Mount the ACU only in an EIA-standard compliant 19” rack.