Comba Telecom Ltd. RX-7W22 사용자 설명서

다운로드
페이지 40
INSTALLATION GUIDE FOR RX7W22 
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 18 
 
 
 
 
3.4.2  PS BDA LED INDICATORS 
The LED indicators helps user to check the equipment status easily.  
 
Table 2: LED Indicators 
Identifier 
Colour 
Indication 
PWR 
Green 
Power indicator. ON = power on; OFF = power off.  
RUN 
Green 
Operation indicator, flashes every second to indicate normal operation. 
ALM 
Red 
Alarm indicator. ON = alarm; OFF = no alarm. 
 
 
3.4.3  GROUNDING CONNECTION 
Ground Connection 
 
To ensure safe operation of the product, a ground (earth) connection is required. For single phase AC 
power source, the product must be grounded by connecting the “earth wire” of the power cord to the ground 
terminal of the AC supply. For operating this product with DC power system (such as rectifiers), the product 
should not be connected to power systems that switch open the return lead because the return lead could 
function as the ground (earth) connection for the equipment.  
 
Protective Ground Connection 
 
The enclosure must be grounded securely by connecting a copper wire (CSA 16mm
2
) to the grounding 
terminal on the equipment/rack, and the other end to a protective ground (i.e. building earth point). An 
internationally acceptable colour code of the ground connection wire is green/yellow.  
 
Such a ground connection implements the “Protective Ground Connection”, and must be connected to the 
equipment at the designated ground point. In general, do not connect the supply before establishing an 
adequate ground (earth) connection. 
 
Construct the ground wire, and use appropriate crimp connectors where necessary. Locate and connect 
the equipment grounding terminal to a protective ground (i.e. building earth point). 
 
3.4.4  RF CABLE CONNECTION 
Single band PS BDA RF cables connection is as follows:  
 
PS BDA MT port  Connects to the feeder cable from service antenna. 
 
PS BDA DT port  Connects to the feeder cable from donor antenna. 
 
 
3.4.5  ETHERNET CONNECTION 
Connect Ethernet with 
‘LAN’ port in the panel, Ethernet type only.