3.3.4  WALL MOUNTING  
  Drill four holes on the wall using the position of four holes on the mounting rack as a guide. Fix the 
mounting rack to the wall using four masonry bolts (M10x110mm).
 
  Install the Mounting Rack2 on the both side of the enclosure.  
  Hang up the equipment and secure the enclosure to the mounting rack.  
 
 
 
Figure 5: PS BDA Wall Mounting 
 
 
 
3.3.5  DRIP-LOOP 
Comba recommends that every horizontal cable entry to the equipment forms a 'U' before its entry to the 
equipment. Water on the cable will drip down at the bottom of the loop and will not accumulate at the 
equipment connectors. 
 
 
 
 
 
Mounting Rack
Masonry bolt
8-M10x110
PS BDA
8-M4x12, Hex socket
with washer bolt