Guardian Instruments, Inc. 
3585 County Rd. 272 #600, Leander, TX 78641      512-260-3554(phone) 
          512-260-3755(fax)
 
  
 
OPERATIONS and TEST MANUAL 
PN: 4952-002 Radios 
Revision 1.0 
 
Manual for 916.5 MHz and 914 MHz Radios 
Released 8/1/01 
 
Regulatory Statement 
 
This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 
 
 
Warning 
 
Any modifications to this device without the express written consent of the party responsible for it’s 
compliance could void the user’s authority to operate the equipment! 
 
 
 
Power Requirements
 
 Input Power Requirements:  6-30 VDC 
 Input Current Drain:   <750 ma with Relay Energized and Backlighting ON 
  
Mounting:  
 
Step1. Use #6 nylon screws to rigidly attach PCB assembly to mount plate. Use Locktite 242 to all 
screws.  
Step 2. Place the screws in the 4 mounting holes in the PCB and tighten to 5 ft-lbs. 
 
Programming: 
 
Step 1. Use the software provided with the board and program using MPLAB and the special 
programming connector.  
Step 2. Verify all programming activities using MPLAB VERIFY function. 
 
Operation: