Configuring the Door Control Unit 
 
InfoProx Entry   
Door Close After Time 
Door Close After Time allows you to configure the length of time the door can 
remain open before an alarm is activated.  
 
Modifying the door close after time option 
After the door strike time is set, the following prompt appears: 
 
Set Drclose=15s 
New Drclose=  s 
To manually access Door Close after Time, press # when in Door Strike 
Time mode. 
To change from the default setting of 15 seconds
1. 
Enter seconds using two digits. This option can be bypassed by 
pressing the # key, accepting the default. The 
Ù key can be used to 
correct any errors made while entering the Door close after Time. 
 
 
Door Close After Time is also known as Door Held 
Time or Shunt Time. 
 
Once the time is set, the next screen in the Configuration menu 
sequence, GIN Configuration, automatically displays. 
 