 2.4  UDL500: Control digital output via hardware trigger
Installation   notes:  We   recommend   professional   grounding   of   the   device   (see   2.1 
Installation   note).   Output   OUT   and   Input   IN   are   potential-free.   Take   care   that   the 
grounding will be sufficient (use second tab connector)!
The potential-free input IN may be used to control the reader by a hardware trigger (e.g. 
tip switch).  The control of the potential-free output OUT can be configured within the 
software. For this the reader has to be operated in trigger mode.
In the following example of circuits, the output OUT has not been potential isolated:
UDL500 housing
V17/01/08
deister electronic GmbH  30890 Barsinghausen  Germany 
7
Wiring & Installation Instructions UDL500