Digital Security Controls Ltd. 02RF5501433 사용자 설명서

다운로드
페이지 32
8
 Receiver Programming
 
3
Enroll & Program Devices
This section describes how to enroll and program:
• wireless devices using zones (WLS904P, WLS906, WLS907, WLS912, WLS914 and
WLS925L)
• wireless keys (WLS909, WLS919)
For more information on these devices, read the instruction sheet included with each
device.
3.1 A Note about Electronic Serial Numbers
An electronic serial number (ESN) is printed on the back of each wireless device. ESNs
are used to enroll the wireless devices with the RF5501-433 keypad.
In order to reduce the occurrence of wireless devices with the same serial number, 6-
digit serial numbers are now printed on the back of each wireless device.
NOTE: 6-digit serial numbers are only supported on the following control panels: PC5010
v2.x and higher, PC5015 v2.2, PC5020, PC5008, PC1555 and PC580.
The 6-digit serial numbers include hexadecimal digits. For instructions on programming,
hexadecimal numbers, see your system 
Installation Manual, section 4: How to Program.
When connecting the RF5501-433 to a PC5010, PC5020 or PC5015 v1.x panel, enter 5-
digit serial numbers only.
When connecting the RF5501-433  to a PC5010 v2.x, PC5015 v2.x, PC5020, PC5008,
PC1555 or PC580 panel follow the instructions below.
Old Wireless Device ESNs
You can use older devices on all versions of the RF5501-433 keypad, even though they
only have a 5-digit ESN. When using older wireless devices:
Enter [0] + 5-digit ESN
3.2 Enroll Wireless Devices Using Zones
Enroll wireless devices which use zones (universal transmitters, motion detectors,
smoke detectors, and panic pendants):
1. At a system keypad, enter [
✱][8][Installer’s code] to go the installer’s programming
section.
2. Enter programming section [804].
3. Enter the 2-digit number corresponding to the zone the device is to occupy ([01] to [32]).
NOTE: Hardwired and wireless devices cannot be assigned to the same zone. PC5108
zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-12 and zones 13-
16). None of the zones assigned to a PC5108 module may be used for wireless de-
vices. For more information on zone assignment, consult your system Installation
Manual.
4. Enter the device’s ESN. The entry 
must be six digits. If an older device with a 5-digit
ESN is being enrolled, add the digit [0] to the beginning of the ESN. (E.g.,
ESN=21234, enter 021234)