Elster Solutions LLC VRT02 사용자 설명서

다운로드
페이지 47
VRT
 
D
IRECT 
G
AS
-M
ETER 
T
RANSPONDER 
I
NSTALLATION
  
CHAPTER
 
4
 
Page 14 
VRT Gas Transponder ― User Guide  
 
AMCO Automated Systems • P/N 52870T010 Rev 1 May 2003 
 
 
2.  Remove the gasket and any adhesive material from the meter. 
•  Use a scraper or putty knife. 
 
3.  Align index wriggler with transponder wriggler, as shown below. 
 
4.  Attach the index to transponder. 
•  Use two (2) appropriate index screws. 
CAUTION: Do not over tighten index screws.  
 
Checking Mechanical Operation 
 
This procedure will verify the attached index rotates freely and 
without resistance. 
 
1.  Rotate the index drive dial 3 times clockwise. 
 
2.  If it turns easily, rotate the drive dial 3 times counterclockwise.  
•  This will remove counts or subcounts from the mechanical 
index.) 
•  If it does not turn easily, first rotate the drive dial 3 times 
counterclockwise to remove subcounts from the mechanical 
index. Second, unscrew the index/transponder assembly 
and repeat from Step 3 of the previous section. 
 
NOTE:  Subcounts added to the electronic index during this 
procedure will be cleared when the index reading is programmed 
into the transponder.  
 
Type A 
Type R 
Type S