Tandberg Data StorageLoader 2U LTO, 1 x 10 LTO-3 052102 사용자 설명서

제품 코드
052102
다운로드
페이지 278
A
PRIL
 2007
S
TORAGE
L
OADER
 2U LTO
201
B
ACKUP
 S
OFTWARE
 R
EPORTS
 
AN
 E
RROR
T
APE
 D
RIVE
 F
AILS
 
WITH
 S
PORADIC
 E
RRORS
Terminator. Check the terminator used on the tape drive. 
Both LTO-2 and LTO-3 SCSI tape drives are Ultra 160 SCSI devices and require 
a minimum Ultra 160 non-RAID SCSI card, Ultra 160 rated SCSI cabling, and 
an Ultra 3 Active SCSI terminator. Cabling and termination rated higher (Ultra 
320, for example) is also acceptable. 
An appropriate terminator is stamped with Ultra 3 or LVD 160 and “Active 
Negation.”
Your library was shipped with the appropriate terminator. If you incorporate 
the library into an existing setup that is not properly terminated, or if the 
original terminator is replaced during setup, you may experience the failures 
described below. 
Failure symptoms include:

Read/Write failure

Bus hangs

Connectivity issues—tape drive not seen on bus or drops off bus

Command failures—commands to this device may fail while commands to 
other devices on the bus may work properly
B
ACKUP
 S
OFTWARE
 R
EPORTS
 
AN
 E
RROR
Your backup software may report an error as a result of a failure to 
communicate with the tape drive(s) or library, a failure by a tape drive to write 
or read data, or because of a software configuration issue. 
F
AILURE
 
TO
 C
OMMUNICATE
 
WITH
 
A
 T
APE
 D
RIVE
Communication problems on the SCSI bus may be reported by the backup 
application as resets, a loss of communication with a tape drive, failure to 
detect a tape drive, I/O device errors, or parity errors. These types of errors 
may occur intermittently. 

If you have a SCSI library, check the tape drive’s installation on the SCSI bus, 
described in 

If you have a Fibre Channel connection to your library (the tape drives 
installed in the library are Fibre Channel), check the Fibre Channel 
connection, described in 
.
! ! ! ! 
Important
Both LTO-2 and LTO-3 SCSI tape drives require an Ultra 3 or 
LVD 160 terminator to function properly on the SCSI bus. An 
inadequate terminator will result in various SCSI bus issues, 
including bus hangs and Read/Write failures.