Texas Instruments Advanced bqMTester Multi-Station Test and Program Board Texas Instruments ADVANCED-BQMTESTER ADVANCED-BQMTESTER 데이터 시트

제품 코드
ADVANCED-BQMTESTER
다운로드
페이지 62
Appendix E
Table 2. Error Code Definitions (continued)
Error Code
Error #
Description
Most Probable Cause
Possible Action
BUS_BUSY
94
SMBus communication
Wrong kind of target
make sure that the target mode
terminated unexpectedly /
connected or target timing is
accepts the SMB command
timed out or the bus was
off Trim oscillator
being sent
busy.
T2H_ERR_BAD_SIZE
95
SMBus communication
Wrong kind of target
make sure that the target mode
terminated unexpectedly /
connected or target timing is
accepts the SMB command
timed out or the bus was
off Trim oscillator
being sent
busy.
ERR_BAD_PAYLOAD_LEN
97
Packet was corrupted
Bad USB connection
Check Version Compatibility
during USB
and USB cable
communication or software
sent in a bad packet
ERR_TMMT_LIST_FULL
98
Not used
ERR_TMMT_BAD_SELECTION
99
Not used
UNKNOWN
100
Unexpected/unknown error
Outdated software Contact TI
UNEXPECTED_ERROR
110
Should not happen
Unexpected error
Hardware not expected to
respond to this error
OUT_OF_MEMORY
111
Not enough memory on
Install more memory
PC
SREC_OPEN_FAIL
221
Srec specified does not
SREC targets a different
Ensure version compatibility
exist or cannot be opened
device than the one detected
between bqMTester software
on the SMBus
'
and Module under Test.
SREC_BAD_START_RECORD
222
Srec not in expected
SREC targets a different
Ensure version compatibility
format
device than the one detected
between bqMTester softare and
on the SMBus
'
Module under Test.
SREC_UNKNOWN_TYPE
223
Srec not in expected
SREC targets a different
Ensure version compatibility
format
device than the one detected
between bqMTester softare and
on the SMBus
'
Module under Test.
SREC_BAD_CHECKSUM
224
Srec not in expected
SREC targets a different
Ensure version compatibility
format
device than the one detected
between bqMTester softare and
on the SMBus
'
Module under Test.
SREC_BAD_RECORD_COUNT
225
Srec not in expected
SREC targets a different
Ensure version compatibility
format
device than the one detected
between bqMTester softare and
on the SMBus
'
Module under Test.
SREC_DEV_MISMATCH
226
SREC targets a different
Ensure version compatibility
device than the one detected
between bqMTester softare and
on the SMBus
'
Module under Test.
CONFIG_OPEN_FAIL
227
Config file not found /
Redo StationSetup.exe
cannot be opened
configuration
CONFIG_UNEXPECTED_EOF
228
Config file not found /
Redo StationSetup.exe
cannot be opened
configuration
CONFIG_BAD_FORMAT
229
Config file format incorrect
Redo StationSetup.exe
configuration
PCFG_DEVVER_MISMATCH
231
Config file device version
Ensure version compatibility
not compatible
between bqMTester softare and
Module under Test.
PCFG_DEV_MISMATCH
232
Config file device not
Ensure version compatibility
compatible
between bqMTester softare and
Module under Test.
PCFG_SRECDEVVER_MISMATCH
233
Srec not compatible with
Ensure version compatibility
current hardware device
between bqMTester softare and
Module under Test.
PCFG_SRECDEV_MISMATCH
234
Srec not compatible with
Ensure version compatibility
current hardware device
between bqMTester softare and
Module under Test.
BCFG_DEVVER_MISMATCH
235
Srec not compatible with
Ensure version compatibility
current hardware device
between bqMTester softare and
Module under Test.
BCFG_DEV_MISMATCH
236
Srec not compatible with
Ensure version compatibility
current hardware device
between bqMTester softare and
Module under Test.
SMBC_LOCKED
260
Unused but reserved for
backward compatibility
516
Unused but reserved for
backward compatibility
38
Error Code Definitions
SLUU397A
February 2011
Revised May 2011
Copyright
©
2011, Texas Instruments Incorporated