Texas Instruments Advanced bqMTester Multi-Station Test and Program Board Texas Instruments ADVANCED-BQMTESTER ADVANCED-BQMTESTER 데이터 시트

제품 코드
ADVANCED-BQMTESTER
다운로드
페이지 62
Appendix E
Table 2. Error Code Definitions (continued)
Error Code
Error #
Description
Most Probable Cause
Possible Action
T2H_NACK
772
No response from target
Target not connected/not
Connect target and check is
powered
correct power is applied
SMBD_LOW
1028
Unused but reserved for
backward compatibility
SMB_LOCKED
1284
Unused but reserved for
backward compatibility
ERR_NOTHINGTODO
5001
Calling the function with
specified values resulted in
nothing being done
ERR_VOLTAGE_LESSTHANZERO
5002
Specified Voltage must be
greater than 0
ERR_TEMPERATURE_LESSTHANZERO
5003
Specified temperature
must be greater than 0
ERR_CURRENT_EQUALSZERO
5004
Specified current cannot
be 0
ERR_NOT_IN_CAL_MODE
5010
Gas gauge was not in
Calibration mode/ could
not be put in calibration
mode
ERR_CALIBRATION_IN_FIRMWARE_FLASHWRITE
5020
Error writing flash in
calibration mode
ERR_CALIBRATION_IN_FIRMWARE_AFE
5021
Error in AFE calibration
Value too large (Overflow) in
firmware
ERR_CALIBRATION_IN_FIRMWARE_PACKV
5022
Error in Pack voltage
Value too large (Overflow) in
calibration
firmware
ERR_CALIBRATION_IN_FIRMWARE_PACKG
5023
Error in Pack gain
Value too large (Overflow) in
calibration
firmware
ERR_CALIBRATION_IN_FIRMWARE_VGAIN
5024
Error in Voltage gain
Value too large (Overflow) in
calibration
firmware
ERR_CALIBRATION_IN_FIRMWARE_CCIGAIN
5025
Error in Current gain
Value too large (Overflow) in
calibration
firmware
ERR_CALIBRATION_IN_FIRMWARE_TMPOFFEXT1
5026
Error in external
Value too large (Overflow) in
temperature 1 offset
firmware
calibration
ERR_CALIBRATION_IN_FIRMWARE_TMPOFFEXT2
5027
Error in external
Value too large (Overflow) in
temperature 2 offset
firmware
calibration
ERR_CALIBRATION_IN_FIRMWARE_TMPOFFINT
5028
Error in internal
Value too large (Overflow) in
temperature offset
firmware
calibration
ERR_CALIBRATION_IN_FIRMWARE_ADCOFF
5029
Error in ADC offset
Value too large (Overflow) in
calibration
firmware
ERR_CALIBRATION_IN_FIRMWARE_BRDOFF
5030
Error in Board offset
Value too large (Overflow) in
calibration
firmware
ERR_CALIBRATION_IN_FIRMWARE_CCIOFF
5031
Error in CC offset
Value too large (Overflow) in
calibration
firmware
ERR_CALIBRATION_IN_FIRMWARE_RDRAWCALD
5032
Error in reading raw
ATA
calibration data
ERR_CALIBRATION_IN_FIRMWARE_RSVD1
5033
Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD2
5034
Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD3
5035
Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD4
5036
Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD5
5037
Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_RSVD6
5038
Reserved for future use
ERR_CALIBRATION_IN_FIRMWARE_UNDEFINED
5039
Unknown error code
Software is obsolete
returned by hardware
ERR_DF_RD_REQ_B4_WR
5041
Data flash cannot be
written before reading the
remaining values in a
given class
ERR_INVALID_DATA_ENTERED
5042
Invalid data entered on
screen
39
SLUU397A
February 2011
Revised May 2011
Error Code Definitions
Copyright
©