Figure 28-3. PWM Count-Down Mode
LOAD
0
COMPB
COMPA
load
zero
cmpB
cmpA
dir
ADown
BDown
Figure 28-4. PWM Count-Up/Down Mode
LOAD
0
COMPA
load
zero
cmpB
cmpA
dir
BUp
AUp
ADown
BDown
COMPB
28.3.4
PWM Signal Generator
Each PWM generator takes the load, zero, cmpA, and cmpB pulses (qualified by the dir signal) and
generates two internal PWM signals, pwmA and pwmB. In Count-Down mode, there are four events
that can affect these signals: zero, load, match A down, and match B down. In Count-Up/Down
mode, there are six events that can affect these signals: zero, load, match A down, match A up,
match B down, and match B up. The match A or match B events are ignored when they coincide
with the zero or load events. If the match A and match B events coincide, the first signal, pwmA, is
generated based only on the match A event, and the second signal, pwmB, is generated based only
on the match B event.
For each event, the effect on each output PWM signal is programmable: it can be left alone (ignoring
the event), it can be toggled, it can be driven Low, or it can be driven High. These actions can be
used to generate a pair of PWM signals of various positions and duty cycles, which do or do not
overlap. Figure 28-5 on page 1937 shows the use of Count-Up/Down mode to generate a pair of
center-aligned, overlapped PWM signals that have different duty cycles. This figure shows the pwmA
and pwmB signals before they have passed through the dead-band generator.