5.3
DDR3 Operation
5.3.1
DDR3 Source Load Regulation
5.3.2
DDR3 Sink/Source Transient
www.ti.com
Test Procedure
1. Set Switch S1 to the OFF position.
2. Ensure DC Source 4 is OFF.
3. Increase V
IN
(DC Source 1) from 0 V to 3.3 V at J1. This is the bias supply required for TPS51200
operation. Using V1, verify that V
IN
is between 3.25 V and 3.35 V.
4. Increase VDDQ (DC Source 2) from 0 V to 1.5 V at J2. This is the reference input. Using V2, verify
that the VDDQ voltage is between 1.45 V and 1.55V.
5. Increase VLDOIN (DC Source 3) from 0 V to 1.5 V at J3. This is the LDO input. Using V3, verify that
the VLDOIN voltage is between 1.45 V and 1.55 V. Ensure that the input wires are short and heavy
(gauge 14 and lower).
6. Set Switch S1 to the ON position.
7. Set Load 1 to between 0 A to 2 A Set Load 2 to between 0 mA and 10 mA.
8. Verify that V3 is between 1.45 V and 1.55 V. Adjust VLDOIN if necessary.
9. Use V4 and V5 to measure the VTT and VTTREF voltage. V4 uses for VTT at TP7 (+) and TP6 (–). V5
uses for VTTREF at TP18 (+) and TP19 (–). VTT and VTTREF both should be approximately 0.75 V.
10. Decrease Load 1 to 0 A.
11. Decrease Load 2 to 0 mA.
12. Set Switch S1 to the OFF position.
13. Continue on the test procedure Section 5.3.2.
1. Remove Load 1 from J5.
2. Ensure that the two jumpers provided in the EVM to short pin1and pin2 are connected at location J7
and J8.
3. Increase DC Source 4 from 0 V to 5 V at J6. This is the bias supply required for transient load
operation. Using V6, verify that the 5VINPUT is between 4.95 V and 5.05 V.
4. Set Switch S1 to the ON position.
5. The TPS51200 is now operating at sink (1.0A) and source (1.0A) load transient.
6. Verify that V3 is between 1.45 V and 1.55 V. Adjust VLDOIN if necessary.
7. Use V4 and V5 to measure the VTT and VTTREF voltage. V4 uses for VTT at TP7 (+) and TP6 (–). V5
uses for VTTREF at TP18 (+) and TP19 (–). VTT and VTTREF should each measure approximately
0.75 V.
8. Use a scope probe to monitor the VTT load transient regulation. The scope probe should be put at TP7
(+) and TP6(–) by setting to AC with 20 MHz bandwidth limiting. Use a vertical resolution of 20 mV per
division and a horizontal resolution of 200
µ
s per division. Use the horizontal cursor to measure
transient load regulation. The measurement should ignore high-frequency switch transition spikes.
Refer to
and the
9. Set Switch S1 to the OFF position.
10. Decrease DC source 4 to 0 V.
11. Decrease DC source 3 to 0 V.
12. Decrease DC source 2 to 0 V.
13. Decrease DC source 1 to 0 V.
SLUU323 – JUNE 2008
Using theTPS51200 EVM Sink/Source DDR Termination Regulator
11