44  
Configuring the Library 
 
The partition mode must be set to Offline if you want to restrict host access to the specified 
partition. 
When you are changing partition mode, be aware of the following information: 
 
The Online/Offline buttons toggle between states. 
 
It is only possible to set a partition offline when the partition is not in use. 
 
Set the button to read Online to take either the physical library or a partition (depending on the 
current view) to an online state. This is the normal operating condition. In this mode, robotics is 
enabled and all host commands are processed. 
 
Set the button to read Offline to take either the physical library or a partition (depending on the 
current view) to an offline state. If only the physical library is taken offline, the library’s partitions 
will not process robotics commands, even though they are online. If only a partition is taken 
offline, neither the physical library nor the other partitions will be affected 
The paths to open the appropriate screens are: 
 
From the RMI, select Operations > Partition Mode 
 
From the FPI, select Operations > Change Partition Mode 
Setting Drive ID 
A SCSI ID is a value between 0–15. Each device on a SCSI bus (including the HBA) needs to have a 
unique ID. Changing the SCSI ID is necessary when there is a duplicate ID on a single bus. Typically, 
the HBA SCSI ID is set to 7. For example, if two tape drives are connected together on the same bus, 
each tape drive must have different SCSI IDs and they must be different from the HBA SCSI ID. 
The library assigns default SCSI IDs to SCSI tape drives. The SCSI ID for drives is based on the bay 
position in the library, and not the drive itself. This means that if a drive is replaced, or moved to a 
different bay, the drive will take on the SCSI ID of the bay that it is installed in. The Set Drive ID 
feature allows the operator to change the SCSI ID for any drive position. The default SCSI ID for the 
drive bays is defined as follows: 
 
Drive Bay 
Default 
SCSI ID 
1 (bottom) 
4 (top) 
 
The drive SCSI ID is configured with the Setup Wizard. After the initial setup of your library you can 
later access the SCSI ID configuration screens directly: 
 
From the RMI, select Setup > Partition/drive 
 
From the FPI, select Setup > Partitions 
If your library includes fibre channel or SAS tape drives, the Setup Drive ID screen shows the world-
wide node name and port name of the drive.  These are not configurable.  
The world-wide node name and port name for drives is based on the bay position in the library, and 
not the drive itself. This means that if a drive is replaced, or moved to a different bay, the drive will 
take on the node name and port name of the bay that it is installed in. 
The node names and port names are unique for each library and are assigned to the library during 
manufacturing.