StorageLibrary Installation and User Guide 
45 
Modifying the Control Path 
The control path tape drive is used to connect a partition to a host application. For normal operation, 
only one tape drive should be selected as the control path for each partition at any one time. By 
default, the lowest tape drive assigned to a partition is designated the control path. In the event that 
the control path connection to the host application fails, you may manually select a new control path 
for the partition. 
 
 Note 
You may need to modify settings in your host application as a result of modifying 
the control path. For details, please refer to your host application documentation. 
 
The control path is configured with the Setup Wizard. After the initial setup of your library you can later 
access the control path configuration screens directly: 
 
From the RMI, select Setup > Partition/Drive 
 
From the FPI, select Setup > Partitions 
Configuring Menu Time-out 
The Menu Timeout feature allows you to configure the timeout delay on the front panel and remote 
management interface. If there has been no activity on the front panel or remote management 
interface for a specified time, the FPI and RMI screens return to the home screens. The menu timeout 
is user settable from 1 to 9 minutes. The default value is 1 minute. 
The menu timeout is configured with the Setup Wizard. After the initial setup of your library you can 
later access the Menu Timeout configuration screens directly: 
 
From the RMI, select Setup > Library 
 
From the FPI, select Setup > Library 
Setting Date and Time 
The library is equipped with a battery backed up real time clock. The time is set initially during 
manufacturing, but needs to be re-set to the local time by the user. As a minimum, it is recommended 
that the library’s date and time be set during initial configuration. The settings are used to log the date 
and time that events have taken place. The library date and time settings can be modified at any time. 
The time is set to a 24 hour clock. For example, four o’clock in the afternoon is entered as 16:00. 
The Date & Time is configured with the Setup Wizard. After the initial setup of your library you can 
later access the Date & Time configuration screens directly: 
 
From the RMI, select Setup > Library 
 
From the FPI, select Setup > Library 
Configuring Barcode Scan 
This feature allows the operator to enable or disable the barcode scanner from the front panel or the 
remote management interface. The default setting for the library is “barcode scanner enabled”. If 
disabled, the library will locate cartridges using the robotics. 
The Barcode Scan is configured with the Setup Wizard. After the initial setup of your library you can 
later access the Barcode Scan configuration screens directly: 
 
From the RMI, select Setup > Library