E. Checking the Gas Supply (Inlet) Pressure
1. Remove  the  supply  (inlet)  pressure  cap  screw  from  the
multifunction gas valve.  Attach a manometer to the stud.
2. Depress  the  machinery  compartment  safety  switch  to
allow the oven to operate.
3. Open the main gas supply valve.  Switch the circuit breaker/
fused disconnect to the ON ("I") position.
4. Start the oven and adjust the temperature controller to the
maximum  setting  (288°C).
5. Measure the supply (inlet) pressure.
6. Switch the oven off.  Close the main gas supply valve, and
switch the circuit breaker/fused disconnect to the OFF ("O")
position.    Remove  the  manometer,  and  replace  the  cap
screw onto the multifunction gas valve.
7. Compare  the  measured  supply  (inlet)  pressure  to  the
nominal pressures shown in the Gas Orifices and Pressure
Specifications  table.
If  the  supply  pressure  is  lower  or  higher  than  the  nominal
pressure,  the  reason  should  be  investigated  and  the  gas
supplier  contacted.
For natural gas ovens, if the measured supply pressure is lower
than 17mbar, or higher than 25mbar, contact the gas supplier.
DO NOT OPERATE THE OVEN or adjust the oven controls.
F. Adjusting the Orifice (Manifold) Pressure and Heat Input
To use the orifice pressure method, you must know the specific
gas type and quality used.  If using the orifice pressure method,
you should double-check the input using the volumetric method.
To use the volumetric method, you must know the heat value
(HuB) of the gas used.  This information is available from your
gas  supplier.
During  these  measurements,  do  not  operate  any  other
appliances that use the same gas meter as the oven.
1. Orifice (Manifold) Pressure Method
a. Check that the main gas supply valve and the circuit
breaker/fused disconnect are in the OFF ("O") position.
b. Remove the regulated (manifold) pressure cap screw
from the multifunction gas valve.  Attach a manometer
to the stud.
c. Remove the cap screw from the pressure adjustment
screw (governor) on the multifunction gas valve.
d. Depress the machinery compartment safety switch to
allow the oven to operate.
e. Open the main gas supply valve.  Switch the circuit
breaker/fused disconnect to the ON ("I") position.
f.
Start the oven and adjust the temperature controller to
the  maximum  setting  (288°C).
g. Adjust  the  pressure  adjustment  screw  as  necessary
to match the correct pressure for the oven's specific
gas  type.    Refer  to  the  Gas  Orifices  and  Pressure
Specifications  table.    Turning  the  adjustment  screw
clockwise  increases  the  flow,  while  turning  it
counterclockwise  reduces  the  flow.
h. Switch the oven off.  Close the main gas supply valve,
and switch the circuit breaker/fused disconnect to the
OFF  ("O")  position.    Remove  the  manometer,  and
replace  the  cap  screws  onto  the  multifunction  gas
valve.
Consumption  (m
3
/hr.)  =
NB (Rated input in kW)
HuB (Heat [Calorific] value
of gas in kW/m3)
        =
Time (in minutes) of
0.1m3  of  gas  usage
2. Volumetric  Method
a. Determine the time of 0.1m
3
 (100 liters) of gas usage
as  follows.
b. Check that the main gas supply valve and the circuit
breaker/fused disconnect are in the OFF ("O") position.
c. Remove the cap screw from the pressure adjustment
screw (governor) on the multifunction gas valve.
d. Depress the machinery compartment safety switch to
allow the oven to operate.
e. Open the main gas supply valve.  Switch the circuit
breaker/fused disconnect to the ON ("I") position.
f.
Start the oven and adjust the temperature controller to
the  maximum  setting  (288°C).
g. Adjust  the  pressure  adjustment  screw  as  necessary
to  match  the  calculated  volume  using  the  time  (in
minutes)  of  0.1m
3
  of  gas  usage.    Turning  the
adjustment screw clockwise increases the flow, while
turning it counterclockwise reduces the flow.
h. Record the reading obtained from the gas meter and
calculate the obtained gas flow.  Compare this value
to  the  information  in  the  Gas  Orifices  and  Pressure
Specifications  table.
i.
Switch the oven off.  Close the main gas supply valve,
and switch the circuit breaker/fused disconnect to the
OFF ("O") position.  Replace the cap screw onto the
multifunction gas valve.
6
Consumption
SECTION 2 - INSTALLATION