Middleby Marshall PS360-U 사용자 설명서

다운로드
페이지 24
17
ENGLISH
SECTION 3 - OPERATION
III. QUICK  REFERENCE:    DIGITAL  TEMPERATURE  CONTROLLER
Display
Shows the Set Point or
the  Actual  Tempera-
ture  in degrees Fahr-
enheit  (F)  or  Celsius
(C).
"SP LOCK" Light
Lights when the set
point  is  locked  out
from  changes.  This
setting  can  only  be
changed  by  service
personnel.
OVERTEMP Light
Lights  when  the  oven
temperature is greater
than 343°C.  Refer to
Quick  Reference:
Troubleshooting  in
this  section.
Temperature Key
Press this key once to
view  the Actual  Tem-
perature  in  the  Dis-
play.
Unlock Key
Press this key together
with the Set Point Key
to  allow  the  Set  Point
to 
be 
changed.
Changes  can  only  be
made for 60 seconds.
Up Arrow and Down Arrow
Keys
Press these keys to adjust
the Set Point up or down.  If
the  Set  Point  will  not
change, refer to  Set Point
Key and Unlock Key in this
section.
Set Point Key
Press this key together
with the Unlock Key to
allow the Set Point to
be  changed.
Changes  can  only  be
made for 60 seconds.
Service Key
For  use  by  ser-
vice  personnel
only.
"ACTUAL TEMP"
Light
Lights  when  the
Actual  Tempera-
ture  is  shown  in
the display.
"SET PT" (setpoint)
Light
Lights when the set
point is shown in the
display.
"HEAT ON" Light
Lights  when  the
burner or heating ele-
ments, as appropriate
for  the  oven  model,
are in operation.